Changing the power voltage setting
%HVXUHWRFKDQJHWKHSRZHUYROWDJHVHWWLQJGHSHQGLQJRQWKHYROWDJHXVHG
1
Go to the function select mode
Press the
CHECK
button
F
twice continuously.
6WDUWWKLVRSHUDWLRQIURPWKHVWDWXVRIUHPRWHFRQWUROOHUGLVSOD\WXUQHGRII
CHECK
is lit and “00” blinks.
Press the temp
button
C
once to set “50”. Direct the wireless remote controller
toward the receiver of the indoor unit and press the
h
button
A
.
2
Setting the unit number
Press the temp
button
C
and
D
to set the unit number “00”. Direct the
wireless remote controller toward the receiver of the indoor unit and press the
min
button
B
.
3
Selecting a mode
Enter 04 to change the power voltage setting using the
C
and
D
buttons.
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
h
button
A
.
&XUUHQWVHWWLQJQXPEHU
EHHSRQHVHFRQG
EHHSVRQHVHFRQGHDFK
EHHSVRQHVHFRQGHDFK
4
Selecting the setting number
Use the
C
and
D
EXWWRQVWRFKDQJHWKHSRZHUYROWDJHVHWWLQJWR9
Direct the wireless remote controller toward the sensor of the indoor unit and press
the
h
button
A
.
5
To select multiple functions continuously
Repeat steps
3
and
4
to change multiple function settings continuously.
6
Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and press
the
button
E
.
Note:
:KHQHYHUFKDQJHVDUHPDGHWRWKHIXQFWLRQVHWWLQJVDIWHULQVWDOODWLRQRU
PDLQWHQDQFHEHVXUHWRUHFRUGWKHFKDQJHVZLWKDPDUNLQWKH³6HWWLQJ´
column of the Function table.
3
CHECK
4
CHECK
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
CHECK
E
C
,
D
F
A
B
)LJ
2
CHECK
CHECK
1
)XQFWLRQVHWWLQJRQWKHUHPRWHFRQWUROOHU
Refer to the indoor unit operation manual.
Function table
Select unit number 00
Mode
Settings
Mode no.
Setting no.
Initial setting
setting
Power failure automatic recovery
Not available
01
1
*2
Available *1
2
*2
Indoor temperature detecting
Indoor unit operating average
02
1
Set by indoor unit’s remote controller
2
Remote controller’s internal sensor
3
LOSSNAY connectivity
Not Supported
03
1
6XSSRUWHGLQGRRUXQLWLVQRWHTXLSSHGZLWKRXWGRRUDLULQOHW
2
6XSSRUWHGLQGRRUXQLWLVHTXLSSHGZLWKRXWGRRUDLULQOHW
3
Power voltage
240 V
04
1
220 V, 230 V
2
6HOHFWXQLWQXPEHUVWRRUDOOXQLWV$/>ZLUHGUHPRWHFRQWUROOHU@>ZLUHOHVVUHPRWHFRQWUROOHU@
Mode
Settings
Mode no.
Setting no.
Initial setting
setting
Filter sign
100 Hr
07
1
2500 Hr
2
No filter sign indicator
3
Fan speed
Silent
08
1
Standard
2
High ceiling
3
–
Fan speed during the cooling
thermostat is OFF
Setting fan speed
27
1
Stop
2
Extra low
3
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.