28
2-3 HEAT operation
Minimum 3 minutes
w
2
ON
Thermostat
Indoor fan
Booster heater
Compressor
ON
LOW or HIGH
LOW or HIGH
ON
OFF
OFF
OFF
ON
OFF
Extra LOW
w
1
Extra LOW
w
1
Hot adjustment
Hot adjustment
w
1 Changeable by indoor
dipswitch SW1- 7
and SW1- 8.
OFF during thermostat OFF
hot adjustment
defrosting
LOW
Operation starts by
P O W E R b u t t o n
ON.
Operation stops by
P O W E R b u t t o n
OFF.
Room temperature
becomes equal to
set temperature.
Room temperature
falls below set tem-
perature.
w
2 Even if the room temperature falls below the set temperature during this period, the compressor will not start until this period has ended.
<HEAT operation time chart>
FILTER
CHECK MODE
TEST RUN
<How to operate>
1
Press POWER ON/OFF button.
2
Press the
button to display “
”
3
Press the
TEMP button to set the desired temperature.
NOTE: The set temperature changes 1°C when the
or
button is pressed one time.
Heating 17°C to 28°C
<Display in HEAT operation>
[DEFROST]
The [DEFROST] symbol is only displayed during the defrost opera-
tion.
[STANDBY]
The [STANDBY] symbol is only displayed from the time the heating
operation starts until the heated air begins to blow.