39
[Operating Procedure]
1
Check the setting items provided by function selection.
If settings for a mode are changed by function selection, the functions of that mode will be changed accordingly. Check all the current settings according to steps
2
to
7
, fill in the "Check" column in Table 1, and then change them as necessary. For factory settings, refer to the indoor unit's installation manual.
2
Switch off the remote controller.
A
Hold down the
FILTER
B
( mode 15 or more) and
TEST
buttons simultaneously for at least two seconds.
FUNCTION
SELECTION
will start to flash,
and then the remote controller's display content will change as shown below.
3
Set the outdoor address.
C
Press the [
CLOCK] buttons (
and
) to select the desired
address. The address changes from "00" to "15".
* If the unit stops after
FUNCTION
SELECTION
flashed for two seconds or "88" flashes in the room temperature display area for two seconds, a transmission error may have occurred.
Check to see if there are any sources of noise or interference near the transmission path.
Note If you have made operational mistakes during this procedure, exit function selection (see step
0
), and then restart from step
2
.
4
Set the indoor unit number.
D
Press the
ON/OFF
button so that "- -" flashes in the unit number display
area.
C
Press the [
CLOCK] buttons (
and
) to select the unit number
of the indoor unit for which you want to perform function selection. The unit
number changes to "00", "01", "02","03",04" and "AL" each time a button is
pressed.
* To set modes 01 to 06 or 15 to 22 select unit number "00".
* To set modes 07 to 14 or 23 to 28 carry out as follows:
• To set each indoor unit individually, select "01" to "04".
• To set all the indoor units collectively, select "AL".
5
Confirm the address and unit number.
E
Press the
MODE
button to confirm the address and unit
number.
After a while, "- - " will start to flash in the mode number display area.
E
When the address and unit number are confirmed by pressing the
MODE
button, the corresponding indoor unit will start fan operation. This
helps you find the location of the indoor unit for which you want to perform function
selection. However, if "00" or "AL" is selected as the unit number, all the indoor
units corresponding to the specified address will start fan operation.
*
"88"
will flash in the room temperature display area if the selected address
does not exist in the system.
Furthermore, if "F" appears and flashes in the unit number display area and the
address display area also flashes, there are no units that correspond to the
selected unit number. In this case, the address and unit number may be incorrect,
so repeat steps
2
and
3
to set the correct ones.
*
When grouping different systems, if an indoor unit other than the
one to which the address has been set performs fan operation,
there may be another address that is the same as the specified one.
In this case, check the DIP switch of the outdoor unit to see
whether such a address exists.
6
Select the mode number.
F
Press the [
TEMP] buttons (
and
) to set the desired mode
number.
(Only the selectable mode numbers can be selected.)
7
Select the setting content for the selected mode.
G
Press the
MENU
button. The currently selected setting number will
flash, so check the currently set content.
F
Press the [
TEMP] buttons (
and
) to select the desired setting
number.
8
Register the settings you have made in steps
3
to
7
.
E
Press the
MODE
button. The mode number and setting number will start
to flash and registration starts.
The mode number and setting number will stop flashing and remain lit, indicating the
end of registration.
* If " - - - "
is displayed for both the mode number and setting number and "
" flashes in the room temperature display area, a transmission error may have occurred.
Check to see if there are any sources of noise or interference near the transmission path.
9
If you wish to continue to select other functions, repeat steps
3
to
8
.
0
Complete function selection.
A
Hold down the
FILTER
TEST
buttons simultaneously for at least two seconds.
After a while, the function selection screen will disappear and the air condi-
tioner OFF screen will reappear.
* Do not operate the remote controller for at least 30 seconds after completing
function selection. (No operations will be accepted even if they are made.)
Note If a function of an indoor unit is changed by function selection after installation is complete, make sure that a " " mark, etc., is given in the "Check"
column of Table 1 to indicate the change.
Address
display section
Unit number
display section
Mode number
display section
00 address
Indoor unit
Fan draft
Remote controller
Main
Sub
Outdoor unit
Designate operation
Example) When the address is set to 01 and the unit number is 02.
Mode number
display section
Mode number 02 = Indoor temperature detection
Setting number display section
Setting number 3 = Remote controller built-in sensor
Setting number 1 = Indoor unit operating average