10
6. Electrical work
5) Assigning a remote controller to each unit
Each unit can be operated only by the assigned remote controller.
Make sure each pair of an indoor unit PC board and a remote controller is assigned
to the same pair No.
6) Wireless remote controller pair number setting operation (Fig. 6-7)
1
Press the SET button with something sharp at the end.
Start this operation from the status of remote controller display turned off.
blinks and Model No. is lighted.
2
Press the
button twice continuously.
Pair No. “0” blinks.
3
Press the temp
buttons to set the pair number you want to set.
If you mistook the operation, press the ON/OFF button and operate again
from procedure 2.
4
Press the SET button with something sharp at the end.
Set pair number is lighted for three seconds then turned off.
A
Pair No. of wireless remote controller
Indoor PC board
0
Factory setting
1
Cut J41
2
Cut J42
3-9
Cut J41, J42
6.3. Function settings
6.3.1. Function setting on the unit (Selecting the unit functions)
1) For wired remote controller (Fig. 6-8)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
1
Go to the function setting mode.
Switch OFF the remote controller.
Press the FILTER
A
and TEST RUN
B
buttons simultaneously and hold
them for at least 2 seconds. FUNCTION will start to blink.
2
Use the
C
buttons to set the refrigerant address (III) to 00.
3
Press
D
button and [--] will start to blink in the unit number (IV) display.
4
Use the
C
buttons to set the unit number (IV) to 00.
5
Press the MODE button
E
to designate the refrigerant address/unit number. [--]
will blink in the mode number (I) display momentarily.
6
Press the
F
buttons to set the mode number (I) to 04.
7
Press the
G
button and the current set setting number (II) will blink.
Use the
F
button to switch the setting number in response to the power supply
voltage to be used.
Power supply voltage
240 V
: setting number = 1
220 V, 230 V : setting number = 2
8
Press the MODE button
E
and mode and the setting number (I) and (II) will change
to being on constantly and the contents of the setting can be confirmed.
9
Press the FILTER
A
and TEST RUN
B
buttons simultaneously for at least two
seconds. The function selection screen will disappear momentarily and the air
conditioner OFF display will appear.
2) For wireless remote controller (Fig. 6-9)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
1
Going to the function select mode
Press the
button
F
twice continuously.
(Start this operation from the status of remote controller display turned off.)
is lighted and “00” blinks.
Press the
temp button
C
once to set “50”. Direct the wireless remote controller
toward the receiver of the indoor unit and press the
button
A
.
2
Setting the unit number
Press the
temp buttons
C
and
D
to set the unit number “00”. Direct the wire-
less remote controller toward the receiver of the indoor unit and press the
button
B
.
3
Selecting a mode
Enter 04 to change the power voltage setting using the
temp buttons
C
and
D
. Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button
A
.
Current setting number:
1 = 1 beep (one second)
2 = 2 beeps (one second each)
3 = 3 beeps (one second each)
4
Selecting the setting number
Use the
temp buttons
C
and
D
to change the power voltage setting to 01
(240 V). Direct the wireless remote controller toward the sensor of the indoor unit
and press the
button
A
.
5
To select multiple functions continuously
Repeat steps
3
and
4
to change multiple function settings continuously.
6
Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and press
the button
E
.
Note: Whenever changes are made to the function settings after installation
or maintenance, be sure to record the changes with a mark in the “Setting”
column of the Function table.
6.3.2. Function setting on the remote controller
Refer to the indoor unit operation manual.
Fig. 6-8
CHECK
CHECK
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
CHECK
Fig. 6-9
CHECK
CHECK
Mode number
Setting number
Refrigerant address
Unit number
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK
DAY
MONITOR/SET
CLOCK
ON/OFF
Fig. 6-7
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
MODEL SELECT