en
2. Parts Names
■
Outdoor unit
Power
Earth
Service Panel
Indoor-Outdoor
Connection wire
Ref. Pipes
■
About the operation method, refer to the operation manual that comes with each remote controller.
3.1. Turning ON/OFF
[ON]
[OFF]
Press the [ON/OFF] button again.
The ON/OFF lamp will come off, and
the operation will stop.
■
Operation status memory
Remote controller setting
Operation mode
Operation mode before the power was turned off
Preset temperature
Preset temperature before the power was turned off
Fan speed
Fan speed before the power was turned off
■
Settable preset temperature range
Operation mode
Preset temperature range
Cool/Dry
19 ~ 30 ºC
Heat
17 ~ 28 ºC
Auto
19 ~ 28 ºC
Fan/Ventilation
Not settable
Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3 minutes.
This is to prevent the internal components from being damaged.
Automatic operation
■
According to a set temperature, cooling operation starts if the room tem-
perature is too hot and heating operation starts if the room temperature
is too cold.
■
During automatic operation, if the room temperature changes and remains
2.0 °C or more above the set temperature for 15 minutes, the air condi-
tioner switches to cool mode. In the same way, if the room temperature
remains 2.0 °C or more below the set temperature for 15 minutes, the
air conditioner switches to heat mode.
Cool mode
15 minutes (switches from
heating to cooling)
Set tempe2.0°C
Set temperature
Set temperature -2.0°C
15 minutes (switches from
cooling to heating)
3.2. Mode Selection
Press the [F1] button to go through the op-
eration modes in the order of “Cool”, “Dry”,
“Fan”, “Auto”, and “Heat”. Select the desired
operation mode.
Cool
Dry
Fan
Auto
Heat
• Operation modes that are not available to
the connected outdoor unit models will not
appear on the display.
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant
system (connected to the same outdoor unit) are already operated in a
different mode. In this case, the rest of the unit in the same group can
only be operated in the same mode.
3. Operation
Press the [ON/OFF] button.
The ON/OFF lamp will light up in green,
and the operation will start.
When “LED lighting” is set to “No,” the
ON/OFF lamp will not light up.
Cool
Room
Set temp.
Mode
Temp.
Fan
Fri
F1
F2
F3
F4