En-9
●
OPERA
TING INSTRUCTIONS ●
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sul
fi
de gas is generated such as a hot spring.
• Where oil is splashed or where the area is
fi
lled with oily smoke (such as cook-
ing areas and factories, in which the properties of plastic could be changed
and damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
I
NSTALLATION PLACE AND
ELECTRICAL WORK
S
PECIFICATIONS
To prevent the effects
of a
fl
uorescent lamp,
keep as far apart as
possible.
wall, etc.
Inverter-type
fl
uorescent lamp
Keep a space to
prevent the pic-
ture distortion or
the noise.
1 m
or more
Radio
100 mm or
more
Well-
ventilated dry
place
200 mm or
more
TV
Cordless
phone or
Portable
phone
3 m or
more
1 m
or more
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
Page 4
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air
fi
lter.
Page 7
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions.
Page 3
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Model
MS-SGH09VC
MS-SGH13VC
Dimensions
H × W × D (mm)
Indoor
295 × 798 × 232
295 × 798 × 232
Outdoor
525 × 718 × 255
525 × 718 × 255
Weight (kg)
Indoor
10
Outdoor
24.5
32.5
Note:
1. Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
2. Guaranteed operating range
Indoor
Outdoor
Upper limit
32°C DB
23°C WB
43°C DB
—
Lower limit
21°C DB
15°C WB
21°C DB
—
DB: Dry Bulb
WB: Wet Bulb
SG79F561H01_en.indd 9
2011/10/03 16:21:47