6 OPTIONS AND PERIPHERAL EQUIPMENT
6.8 Selection example of wires
167
6
Example of selecting the wire sizes
Use the 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire) for wiring. The following shows the wire size
selection examples.
■
200 V class
*1 Be sure to use the size of 2 mm
2
for compliance with the IEC/EN/UL/CSA standard.
*2 The wire size shows applicable size of the servo amplifier connector and terminal block. For wires connecting to the servo motor, refer to
the user's manual of each servo motor.
Selection example of crimp terminals
■
200 V class
Precautions
• Crimp terminals are used only for ground wiring.
Servo amplifier
Wire [mm
2
]
L1/L2/L3
L11/L21
P/C
U/V/W
MR-J5-10_
2 (AWG 14): a
1.25 to 2 (AWG 16 to 14)
2 (AWG 14)
AWG 18 to 14
MR-J5-20_
MR-J5-40_
MR-J5-60_
MR-J5-70_
MR-J5-100_
MR-J5-200_ (3-phase power
supply input)
AWG 18 to 10
MR-J5-200_ (1-phase power
supply input)
3.5 (AWG 12): b
MR-J5-350_
MR-J5W2-22G
2 (AWG 14): a
2 (AWG 14)
AWG 18 to 14
MR-J5W2-44G
MR-J5W2-77G
2 (AWG 14): b
MR-J5W2-1010G
2 (AWG 14): a
MR-J5W3-222G
2 (AWG 14): c
MR-J5W3-444G
2 (AWG 14): c
Symbol
Servo amplifier-side crimp terminal
Manufacturer
Crimp terminal
Applicable tool
a
R2-4
YHT-2210
JST (J.S.T. Mfg. Co., Ltd.)
b
3.5-4
YHT-2210
c
8-4
14-4
YA-4