6.3 FLOW CHART OF SELF-CHECK
(1) Trouble shooting with self-check
This refrigerator has self-check feature to clarify and indicate where & what the trouble is. It can be checked that
there is something wrong with electronic circuit and electric parts.
Remark
(2) Timing of self-check
Defrost heater and related parts : Self-check is conducted after defrosting.(Make sure to confirm the display before unplugging
because it is automatically reset once the power cord is pulled out.)
Ice maker and related parts :
To check the ice- making and then, check the blink amount of LED see the reference as (3)
Fan motor and related parts :
To check the blink amount of LED see the reference as (3)
Thermistor and related parts :
Self-check is continuously working.
Caution: The self-check will automatic start to begin power supply. But in the portion of the abnormality show the detail as (3) .
And the caution checking couldn't be summarized, please use self-check means by using operation panel.
Self-check
Press Ice making stop button
Was trouble
displayed?
Locate the trouble according to
LED indication.(See page
Disconnect power plug
Repair/replace defective part(s)
according to LED indication
Connect power plug
∗
Press Ice making stop button
Self-check ,Ice making stop LED
blink during the operational test
of automatic ice maker.
Check the parts whose
Abnormalities cannot be
detected by self-
check.(Remark.1)
Is error no
longer
displayed?
Self-check is finished.
Slide room
Refrigerator room
Ice making
stop LED
Refrigerator Freezer
Ice maker off
No
No
Yes
Yes
∗
Wait 10 minutes before
inserting the cord once it's
unplugged.(If the cord is
plugged in within 10
minutes,trouble may be
display.)
During the ice making test
mode,watch the operation of ice
maker gear box and water pump in
refrigerator.
Is trouble no longer
displayed?
No
1.) Self-check cannot detect abnormalities of the
following parts. See page 11~13 for trouble
criterion of main parts.
- Freezer & refrigerator door sw NG
- Thermo heater NG ( Water pipe / Vegetable
case heater etc.)
- Motor damper NG
- Water pump motor NG
2.) If the abnormality is found when power is
turned on, compressor and fan motor will be
suspended for 20 minutes.
15
Содержание MR-C375C-OB-A
Страница 2: ......
Страница 9: ... SKELETON WIRING DIAGRAM MR C375C A MR C375CL A MR C405C A MR C405CL A 3 WIRING DIAGRAM 7 ...
Страница 12: ...MR C375C A MR C375CL A MR C405C A MR C405CL A 5 NAMES OF PARTS 10 ...
Страница 26: ...DOOR BODY PARTS MR C375C A MR C375CL A MR C405C A MR C405CL A 8 PARTS LIST 24 ...
Страница 28: ...BODY PARTS MR C375C A MR C375CL A MR C405C A MR C405CL A 26 ...
Страница 30: ...ELECTRICIAL PARTS MR C375C A MR C375CL A MR C405C A MR C405CL A 28 ...
Страница 32: ...ACCESSORY AND UNIT PARTS MR C375C A MR C375CL A MR C405C A MR C405CL A 30 ...