En-3
E
E
190 mm or more
Air outlet
Where airflow
is not blocked.
185 122
190 mm or more
Air inlet
200 mm
or more
Ceiling surface
Ceiling surface
Grille
Ceiling surface
1-4. INSTALLATION DIAGRAM
Units should be installed by licensed contractor according to local code
requirements.
Be sure to use wall hole sleeve
K
to prevent indoor/outdoor
connecting wire
D
from contacting metal parts in the wall and to
prevent damage by rodents in case the wall is hollow.
ACCESSORIES
Check the following parts before installation.
Alkaline battery (AAA) for
2
Drain hose (with insulation)
1
Special washer (with cushion, 4 pcs)
8
Installation template
1
Fixing screw for M5 × 30 mm
4
Band
1
Fixing screw for 4 × 16 mm
2
Remote controller
1
Remote controller holder
1
Fixing screw for 3.5 × 16 mm (Black)
2
PARTS TO BE PROVIDED AT YOUR SITE
A
Refrigerant pipe
1
B
Drain pipe (O.D. 26)
1
C
Installation tools (See 1-3)
1
D
Indoor/outdoor unit connecting wire*
1
E
Suspension bolt (M10)
4
F
Nut with flange (M10)
8
G
Nut (M10)
4
H
Insulating material for
A
(Heat resistant foamed polyethylene,
specific gravity 0.045, thickness more
than 14 mm)
1
J
Insulating material for
B
(Foamed polyethylene, specific grav
-
ity 0.03, thickness more than 10 mm)
1
K
Wall hole sleeve
1
L
Parts for mending wall hole
(putty, cover)
1
M
Pipe fixing band
2 to 7
N
Fixing screw for
M
2 to 7
P
Piping tape
1 to 5
* Note:
Place indoor/outdoor unit connecting wire
D
at least 1 m away from the TV antenna
wire.
Service space
• The dimensions of ceiling opening can be regulated within the range
shown in following diagram; so center the main unit against the open
-
ing of ceiling, ensuring that the respective opposite sides on all sides
of the clearance between them becomes identical.
After the leak test, apply insulating material tightly so that there
is no gap.
When the piping is to be attached to a wall containing metals (tin
plated) or metal netting, use a chemically treated wooden piece 20
mm or thicker between the wall and the piping or wrap 7 to 8 turns
of insulation vinyl tape around the piping.
To use existing piping, perform COOL operation for 30 minutes and
pump down before removing the old air conditioner. Remake flare
according to the dimension for new refrigerant.
185
Indoor unit
Wall hole
sleeve
K
Seal the wall hole
gap with putty
L
.
Fix the pipe to wall
with pipe fixing
band
M
.
Cut off the
extra length.
Pipe fixing band
M
Fixing screw
N
Wall hole cover
L
WARNING
To avoid risk of fire, embed or protect the refrigerant
piping.
External damage on the refrigerant piping can be
cause of fire.
IMPORTANT NOTES
Check that cabling will not be subject to wear, corrosion, excessive
pressure, vibration, sharp edges or any other adverse environmental
effects. The check shall also take into account the effects of aging or
continual vibration from sources such as compressors or fans.