background image

4

Do not cover an air outlet or 

air intake with laundry, cloth, 

curtain, etc.

This results in poor ventilation and 

may 

cause heat generation/fire

.

Do not put vases or any other 

objects filled with water on the unit.

Water may leak into the unit adversely 

affecting electric insulation and 

cause 

electric shock and/or fire

 by short-

circuiting.

Do not use the unit in a  

bathroom or other  

location where it is  

likely to come into  

contact with water, or wash it with 

water.

Exposure to water may 

result in fire or electric 

shock

 caused by an electric leak.

Do not use the unit 

where it may be exposed 

to direct sunlight or other 

weather conditions. 

(This unit is for indoor 

use only.)

This may 

cause overheating, electric shock 

and/or fire

 caused by an electric leak.

Do not use the unit in 

narrow, enclosed places 

such as inside closets, 

between pieces of 

furniture, etc.

This results in poor ventilation and may 

cause heat generation and/or fire

.

Do not use combustion 

appliances in the path of 

the air outlet.

This may 

cause 

incomplete combustion 

in the appliance.

Do not use the unit in places that 

may be subject to oil or flammable 

gas leakage.

Such a leak around the unit may 

cause 

combustion and fire

.

In addition, chemicals and solvents 

evaporated in the air may deteriorate the unit 

(crack the main body) and cause water in the 

tank to leak, 

resulting in damage to property

.

Do not use the unit in places 

where chemicals are used 

(such as hospitals, factories, 

laboratories or beauty salons). 

Chemicals and solvents evaporated in 

the air may harm the unit and cause 

water in the tank to leak, 

resulting in 

damage to property

.

Do not use the unit for special 

purposes, such as  

preservation of food,  

art or scientific works. 

This may 

negatively  

affect the quality 

of the items stored.

Do not point airflow from the  

unit directly at the body for  

a prolonged period of  

time. 

Be especially careful when  

using the unit where there  

is someone who is unable to adjust the 

humidity (infant, child, or elderly person). 

If air-flow is directed at the body for long 

periods, it may 

harm one’s physical condition 

and lead to dehydration

.

Do not stand on, sit on or lean 

against the unit. Do not pull the 

unit by the downward air outlet.

As the unit is on wheels, it may move, tip 

over, or fall 

causing personal injury

Do not remove the Styrofoam 

from the floating element. 

The floating element will not  

be able to detect a full tank  

resulting in water leakage,  

which may damage surrounding 

objects or cause electric shock and/or 

an electric leak

.

Do not drain water continuously 

if there is a possibility that 

temperature around the hose 

could drop to freezing point. 

Water inside the hose may freeze and 

prevent the water in the tank from flowing 

out. The water may leak from the unit and 

damage surrounding objects

.

Install the unit in a location where 

the floor is flat and stable. 

If the unit falls over, the water collected 

in the water tank may leak 

damaging 

surrounding objects and in turn result 

in fire or electric shock caused by an 

electrical leak

.

Before moving the unit always 

switch it off, unplug it and remove 

water from the water tank.

Moving the unit with water in its tank may 

cause the water to leak and 

damage the 

surrounding objects and in turn result 

in electric shock and/or an electric leak

.

After emptying the tank, transport the 

unit by grasping the handle firmly.

Losing your footing while carrying the 

unit may 

cause personal injury or 

damage to the floor

.

CAUTION

Precautions (Cont.)

e_mj_e100ar_h_cs55j.indd   4

2020/07/27   15:34:59

Содержание MJ-E100AR-H

Страница 1: ...Storage 21 z z Troubleshooting 22 z z Specifications 24 z z Disposal 24 DEHUMIDIFIER MODEL MJ E100AR H INSTRUCTION MANUAL Features z z 2 types of laundry mode z z Independent air purifying function z z Bathroom mildew guard Operating Troubleshooting English Before Using the Unit This appliance is designed for use in Hong Kong and Macau only and please do not use in any other countries z z This app...

Страница 2: ...H P 10 P 10 P 12 13 Tips on Drying Laundry P 11 When you want to perform automatic operation When you want to perform continuous operation When you want to set the humidity Reducing blowing sound and performing continuous operation HIGH AUTO EASY LOW P 12 13 When you want to dehumidify MILDEW GUARD P 12 14 When you are worried about mildew in the bathroom AIR PURIFIER P 15 When you want to clean t...

Страница 3: ...e unit near heat generating devices such as stoves fan heaters etc The plastic parts may melt and cause fire Do not put your fingers or any long object into the air intake outlet Do not touch the swing louvre The internal fan rotates at high speeds and such actions may result in injury Do not attempt to repair disassemble or modify the unit This may result in fire and or electric shock Refer servi...

Страница 4: ...h as preservation of food art or scientific works This may negatively affect the quality of the items stored Do not point airflow from the unit directly at the body for a prolonged period of time Be especially careful when using the unit where there is someone who is unable to adjust the humidity infant child or elderly person If air flow is directed at the body for long periods it may harm one s ...

Страница 5: ... the unit resulting in malfunction Should you incline the unit accidentally contact the place of purchase for advice Grasp the plug and remove from the power socket When removing the plug from the power socket do not pull on it diagonally or by the cord as this may cause the projections wiring to be damaged resulting in a short circuit electric shock or fire Switch the unit off and unplug from the...

Страница 6: ...of the room is thus reduced by repeating the above steps The amount of dehumidifying becomes less in winter When the temperature and humidity are low the amount of water collected is decreased In winter because the temperature is lower than in summer the effect of the dehumidifier is greatly reduced as shown in the graph below Although only a little water collects in the tank this is not a malfunc...

Страница 7: ...rticle filter and a blue air freshener filter Particle filter The fine particle filter removes pollen and dust particles Diameter of pollen approx 10 100 μm Air freshener filter A special deodorant and anti bacterial agent antiallergen anti virus and sterilization are contained in the fibres of the silver ion filter Cigarette smoke and toxins found in smoke such as carbon monoxide cannot be remove...

Страница 8: ...oom exceeds 75 is flashing activating the dehumidifier is recommended If the High Humidity warning is not used remove the power plug from the power socket LAUNDRY Lamps LAUNDRY Switch P10 ON OFF TIMER Switch P17 POWER Lamp POWER Switch MODE Switch P12 AIR PURIFIER Lamp AIR PURIFIER Switch P15 DRYING INSIDE Lamp DRYING INSIDE Switch P18 LCD Display FULL Lamp P19 Lights when the tank is full of wate...

Страница 9: ...er ion filter inside the tabs on the pre filter 4 Set the pre filter Insert the bottom tabs into the unit until they click Strips Tabs 4 Note Make sure the silver ion filter is attached to the unit If it is not fine dust will enter inside the unit and cause a malfunction Carrying the Unit Hold the handle and move it Wheels can be used to move the unit First make sure to remove water from the water...

Страница 10: ...NIGHT LAUNDRY It is recommended for reducing the noise emitted from the unit The drying time is longer than that of INTELLIGENT LAUNDRY The unit stops dehumidifying when the water tank becomes full and the blower begins to operate Operating each operation mode Operation mode Automatic stop INTELLIGENT LAUNDRY Operates for 1 to 12 hours NIGHT LAUNDRY Operates for 1 to 12 hours Information z z Remov...

Страница 11: ...that each part can get the blowing air About the Room for Hanging Clothes z z In a small room it is recommended that the door and window be closed before dehumidifying It is effective not only to dehumidify but also to dry the laundry as soon as possible z z When the room temperature is low such as in winter Use a heater in combination with the dehumidifier in order to raise the room temperature t...

Страница 12: ... off the unit restarts at the previous setting z z The humidity cannot be set in modes other than AUTO z z Operation stops when the tank is full To restart operation remove water from the tank If a continuous drainage hose is set the dehumidifier will operate continuously P20 z z In the case of a power outage during operation the dehumidifier will restart operation upon restoration in the operatio...

Страница 13: ...r motor is decreased It is recommended when you want to dehumidify with lower blower sounds Information Sometimes it would take a long time to bring down the humidity depending on opening and closing frequency of the room door or the size or shape of the room To confirm the humidity setting After displaying the current humidity setting is displayed After 3 seconds After approximately 3 seconds the...

Страница 14: ...to the fungus type and conditions of the room e g Under the containers of the bathroom deeper inside of closets and behind furniture and places with bad air flow z z Places such as inside of the bathtub under containers or where the blowing air cannot reach cannot be dried z z This mode does not remove existing mildew scales and sticky liquids around the sinkhole z z When it is used with the OFF T...

Страница 15: ...s 2 Press z AIR PURIFIER lamp lights To return to the previous mode press the AIR PURIFIER switch again Blip Blip z AIR PURIFIER The unit cleans the air by passing it through the pre filter and silver ion filter The dehumidifier function is disabled Information z The air passes through the silver ion filter in all modes cleaning the air even if the AIR PURIFIER lamp is not lit z Cigarette smoke an...

Страница 16: ... louvre direction by hand To dehumidify closets z z Rear The louvre swings to send air to the back of the unit The louvre has a variety of angles so there may be a small amount of air coming from the downward outlet Approximately 120 Approximately 90 60 30 The louvre moves slowly through the last 30 of the swing as it takes shorter time to traverse the upward arc than the rear arc when louvre move...

Страница 17: ...10 14 Set the DRYING INSIDE auto operation as desired P18 z z Select the louvre swing direction P16 3 Confirm the time setting by pressing the POWER switch z z The timer display lights g The ON TIMER is set If both the timer display and operation mode indicator blink it means the POWER switch is not pressed An alarm blip blip sounds for 1 minute z z The remaining time will decrease one hour after ...

Страница 18: ... INSIDE switch when the POWER is ON The DRYING INSIDE lamp turns off Manual Operation The DRYING INSIDE operation can only start when the POWER is OFF Blip Press while the POWER is OFF z z DRYING INSIDE operation starts The DRYING INSIDE lamp flashes the humidity indicator turns off and the louvre stops in the vertical position DRYING INSIDE Operation z z DRYING INSIDE operation ends The DRYING IN...

Страница 19: ...orbidden except for pressing the POWER switch z z In OFF TIMER operation the FULL lamp is ON as indicator In NIGHT LAUNDRY mode z z When the water tank becomes full the unit stops dehumidification but the air supply continues Though the FULL lamp lights there will be no warning sound The air supply continues even if the water tank has been removed 3 Slide the tank lid to close the tank 4 Check the...

Страница 20: ... and cracks z z If it is hard to insert the hose put it in water and then insert it Do not use oils or lubricants z z Inspect the hose once every 2 weeks Insects or dirt deposits in the hose may cause leakage Note CAUTION Do not drain water continuously if there is a possibility that temperature around the hose could drop to freezing point Water inside the hose may freeze and prevent the water in ...

Страница 21: ...on the filter but they will not affect the performance z z The filter can be soaked for a total of eight times After that replace it with a new one 4 Dry the silver ion filter well 5 Set the silver ion filter 6 Set the pre filter Soak in cool or warm water for about 30 minutes Do not use detergent or hot water Also do not use a brush or similar tool to scrub the filter or rub the filter while soak...

Страница 22: ...unction The water tank contains liquid or white water residue z z When the power lamp is ON it operates intermittently z z When the operation ends the louvre closes The louvre remains open when it stops z z The residue is from the dirt in the air Clean according to the Maintenance procedures P21 There is black residue on the inside of the water tank and lid z z Check to see whether the power cord ...

Страница 23: ...e The air blowing sound changes in volume The unit produces a simmering sound The unit produces a buzz that sounds intermittently or the compressor does not activate When first used z z The temperature of heat exchanger goes up rapidly causing transient odor z z The discharged moisture may emit an odor It is common that the silver ion filter cannot eliminate all the odors and the odors can be abso...

Страница 24: ...ps www mitsubishielectric com hk en Model MJ E100AR H Power supply Single phase 220 V 50 Hz Condition Temperature 26 7 C 30 C Relative humidity 60 80 Dehumidifying capacity 1 10 0 L day 18 0 L day Power consumption 175 W 205 W Recommended room size 2 HIGH 3 42 m2 EASY 28 m2 Water tank capacity Stops automatically at approx 4 7 L Weight 14 5 kg Dimensions H W D 594 mm 372 mm 281 mm ZT936Z236H01 Dis...