13
INDOOR UNIT DISPLAY SECTION
9-1. COOL ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF)(
MFZ-KJ25/35/50VE
)/ STOP/OPERATE (OFF/ON)(
MFZ-KJ25/35/50VE2
) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons TEMP or button to select the desired temperature. The setting range is 16 - 31°C.
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
3. Indoor fan speed control
When the thermostat turns OFF, the indoor fan operates at the setting fan speed.
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
The unit is operating to
reach the set temperature
About 2°C or more
away from set tempera-
ture
The room temperature is
approaching the set tem-
perature
About 1 to 2°C from
set temperature
Standby mode (only during
multi system operation)
—
Lighted
Blinking
Not lighted
9-2. DRY ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF)(
MFZ-KJ25/35/50VE
)/ STOP/OPERATE (OFF/ON)(
MFZ-KJ25/35/50VE2
) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select DRY mode with OPERATION SELECT button.
(3) The set temperature is determined from the initial room temperature.
1. Coil frost prevention
Coil frost prevention works the same way as that in COOL mode. (9-1.1.)
2. Low outside temperature operation
Low outside temperature operation works the same way as that in COOL mode. (9-1.2.)
3. Indoor fan speed control
Indoor fan speed control works the same way as that in COOL mode. (9-1.3.)
However in AUTO setting, the fan speed changes.
9-3. FAN ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF)(
MFZ-KJ25/35/50VE
)/ STOP/OPERATE (OFF/ON)(
MFZ-KJ25/35/50VE2
) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select FAN mode with OPERATION SELECT button.
(3) Select the desired fan speed. When AUTO, it becomes Low.
Only indoor fan operates.
Outdoor unit does not operate.
NOTE:
Temperature cannot be set during FAN mode.
OBH666C