background image

Outdoor unit

N

AME OF EACH PART

P

REPARATION BEFORE OPERATION

Indoor unit

Remote controller

Appearance of the outdoor unit may differ from some models.

Display and operation section 

(When the front grille is opened)

Operation indicator lamp

Emergency operation switch
Air outlet selection switch

Remote control
receiving section

Front grille

Fan guard

Vertical vane

Air outlet

Horizontal vane

Catechin air fi lter

Damper

Air cleaning fi lter (Anti-

AllergyEnzyme Filter, 

blue bellows type)

Air inlet

Vertical vane

Air outlet

Air inlet

(back and side)

Piping

Drainage hose

Air outlet

Drain outlet

Remote controller 
holder

•  Install the remote control-

ler holder to a place where 

the signal can be received 
by the indoor unit.

Use the remote controller provided with the unit only.

Do not use other remote controllers.

Signal transmitting section
Distance of signal : 

About 6 m

Beep(s) will be heard 

from the indoor unit 

when the signal is 

received.

Operation display 

section

ON/OFF

(operate/stop) 

button

Temperature buttons 

 Page 4 

Operation 

select button

 Page 4 

ECONO COOL

button 

 Page 6 

Off-timer button 

 Page 6 

On-timer button 

 Page 6 

VANE control
button 

 Page 5 

TIME set buttons 

 Page 3, 6 

Increase time
Decrease time

CLOCK set button

 

 Page 3 

RESET button 

 Page 3 

Lid

Slide down to open

FAN speed
control button

 Page 5 

i-save button 

 Page 6 

Before operation: 

Insert the power supply plug into the power outlet and/or turn the breaker on.

Installing the remote controller batteries

3.

 Press TIME buttons to 

set time

 

Each press increases/
decreases time by 1 

minute (10 minutes 

when pressed longer).

•  Press RESET and CLOCK gently using a thin stick.

 

If the RESET button is not pressed, the remote controller 
may not operate correctly.

Setting current time

1.

 Remove the front lid

2.

 Insert AAA

alkaline batteries

3.

 Install the front lid

•   Make sure the polarity of the batteries is correct.

•   Do not use manganese batteries. The remote controller could malfunction.
•   Do not use rechargeable batteries.

•   Replace all batteries with new ones of the same type.

•  Batteries can be used for approximately 1 year. However, batteries with expired 

shelf lives last shorter.

1.

 Press RESET

2.

 Press CLOCK

4.

 Press CLOCK again

En-3

● OPERATING INSTRUCTIONS ●

JG79A146H02_en.indd   3

2009/07/22   9:23:44

Содержание MFZ-FB50VA

Страница 1: ...English FLOOR TYPE AIR CONDITIONERS INDOOR UNIT MFZ FB50VA OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating in structions before use ...

Страница 2: ... finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside is rotating at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock In this case consult your ...

Страница 3: ...n the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer...

Страница 4: ...e buttons Page 4 Operation select button Page 4 ECONO COOL button Page 6 Off timer button Page 6 On timer button Page 6 VANE control button Page 5 TIME set buttons Page 3 6 Increase time Decrease time CLOCK set button Page 3 RESET button Page 3 Lid Slide down to open FAN speed control button Page 5 i save button Page 6 Before operation Insert the power supply plug into the power outlet and or turn...

Страница 5: ...cator Green Lighted Orange Lighted Green Blinking Orange Blinking Not lighted Indication Operation state Difference between target tem perature and room temperature This shows that the air conditioner is op erating to reach the target temperature Please wait until the target temperature is obtained About 2 C or more This shows that the room temperature is approaching the target temperature About 2...

Страница 6: ...ati cally moves to position 1 after 0 5 to 1 hour to prevent water dripping Swing The vane will move up and down intermittently Select to blow air from the upper and lower air outlets Air will blow only from the upper outlet in the following conditions During COOL When the room temperature is close to set tempera ture When the air conditioner has operated for 2 hours During DRY operation During HE...

Страница 7: ...COOL and HEAT This ena bles you to select your preferred setting with a single push of the button ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 2 C higher auto matically Press again to cancel ECONO COOL operation Pressing also cancels ECON...

Страница 8: ...closing the grille Air cleaning filter Clean every 3 months Soak the filter together with its frame in lukewarm water and wash it After cleaning dry it well in shade and put it back to its original position Install all tabs of the air filter Replace it with a new air cleaning filter every year for best perform ance Parts Number MAC 415FT E Air filter Catechin air filter Clean every 2 weeks Remove dirt b...

Страница 9: ...ing op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the...

Страница 10: ...from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly To prevent the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a space to prevent the picture distortion or the noise Ra...

Страница 11: ...En 10 ...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A146H02 ...

Отзывы: