background image

 CAUTION

Do not step on an unstable bench to operate or clean the 
unit.

•  This may cause injury if you fall down.

Do not pull on the power cord.

•  This may cause a portion of the core wire to break, which may 

cause overheating or fi re.

Do  not  charge  or  disassemble  the  batteries,  and  do  not 

throw them into a fi re.

•  This may cause the batteries to leak, or cause a fi re or explo-

sion.

Do not operate the unit for a long time at high humidity (80% 
RH or more), such as with a door or window left open.

•  The water condensation in the air conditioner may drip down, 

wetting or damaging the furniture.

Do not use the unit for special purposes, such as storing 
food, raising animals, growing plants, or preserving preci-
sion devices or art objects.

•  This may cause deterioration of quality, or harm to animals 

and plants.

Do not expose combustion appliances to direct airfl ow.

•  This may cause incomplete combustion.

Before cleaning the unit, switch it OFF and disconnect the 
power plug or turn the breaker OFF.

•  This may cause injury, since the fan inside is rotating at high 

speeds during operation.

When the unit will be unused for a long time, disconnect the 
power plug or turn the breaker OFF.

•  Otherwise, the unit may accumulate dirt, which may cause 

overheating or fi re.

Replace  both  batteries  of  the  remote  controller  with  new 
ones of the same type.

•  Using  an  old  battery  together  with  a  new  one  may  cause 

overheating, leakage, or explosion.

If the battery fl uid comes in contact with your skin or clothes, 

wash them thoroughly with clean water.

•  If the battery fl uid comes in contact with your eyes, wash them 

thoroughly  with  clean  water  and  immediately  seek  medical 

attention.

Ensure that the area is well-ventilated when the unit is oper-
ated together with a combustion appliance.

•  Inadequate ventilation may cause oxygen starvation.

Turn the breaker OFF when you hear thunder and there is a 
possibility of a lightning strike.

•  The unit may be damaged if lightning strikes.

After the air conditioner is used for several seasons, per-
form  inspection  and  maintenance  in  addition  to  normal 
cleaning.

•  Dirt or dust in the unit may create an unpleasant odor or clog 

the drain passage, and cause water to leak from the indoor 

unit.  Consult  your  dealer  for  inspection  and  maintenance, 

which require specialized knowledge and skills.

 WARNING

Consult your dealer for installing the air conditioner.

•  It should not be installed by the user since installation requires 

specialized knowledge and skills. An improperly installed air 

conditioner may cause water leakage, fi re, or electric shock.

Provide a dedicated power supply for the air conditioner.

•  A  non-dedicated  power  supply  may  cause  overheating  or 

fi re.

Do not install the unit where fl ammable gas could leak.

•  If gas leaks and accumulates around the outdoor unit, it may 

cause an explosion.

Earth the unit correctly.

•  Do not connect the earth wire to a gas pipe, water pipe, light-

ning rod, or a telephone ground wire. Improper earthing may 

cause electric shock.

 CAUTION

Install an earth leakage breaker depending on the installa-
tion  location  of  the  air  conditioner  (such  as  highly  humid 
areas).

•  If an earth leakage breaker is not installed, it may cause electric 

shock.

Ensure that the drain water is properly drained.

•  If the drain passage is improper, water may drip down from 

the indoor/outdoor unit, wetting and damaging the furniture.

In case of an abnormal condition

 

Immediately stop operating the air conditioner and consult your dealer.

S

AFETY PRECAUTIONS

Do not operate switches with wet hands.

•  This may cause electric shock.

Do not clean the air conditioner with water or place an object 

that contains water, such as a fl ower vase, on it.

•  This may cause fi re or electric shock.

Do not step on or place any object on the outdoor unit.

•  This may cause injury if you or the object falls down.

.

For installation

En-2

JG79A146H02_en.indd   2

2009/07/22   9:23:41

Содержание MFZ-FB50VA

Страница 1: ...English FLOOR TYPE AIR CONDITIONERS INDOOR UNIT MFZ FB50VA OPERATING INSTRUCTIONS For user To use this unit correctly and safely be sure to read this operating in structions before use ...

Страница 2: ... finger a stick or other objects into the air inlet or outlet This may cause injury since the fan inside is rotating at high speeds during operation In case of an abnormal condition such as a burning smell stop the air conditioner and disconnect the power plug or turn the breaker OFF A continued operation in the abnormal state may cause a malfunction fire or electric shock In this case consult your ...

Страница 3: ...n the breaker OFF when you hear thunder and there is a possibility of a lightning strike The unit may be damaged if lightning strikes After the air conditioner is used for several seasons per form inspection and maintenance in addition to normal cleaning Dirt or dust in the unit may create an unpleasant odor or clog the drain passage and cause water to leak from the indoor unit Consult your dealer...

Страница 4: ...e buttons Page 4 Operation select button Page 4 ECONO COOL button Page 6 Off timer button Page 6 On timer button Page 6 VANE control button Page 5 TIME set buttons Page 3 6 Increase time Decrease time CLOCK set button Page 3 RESET button Page 3 Lid Slide down to open FAN speed control button Page 5 i save button Page 6 Before operation Insert the power supply plug into the power outlet and or turn...

Страница 5: ...cator Green Lighted Orange Lighted Green Blinking Orange Blinking Not lighted Indication Operation state Difference between target tem perature and room temperature This shows that the air conditioner is op erating to reach the target temperature Please wait until the target temperature is obtained About 2 C or more This shows that the room temperature is approaching the target temperature About 2...

Страница 6: ...ati cally moves to position 1 after 0 5 to 1 hour to prevent water dripping Swing The vane will move up and down intermittently Select to blow air from the upper and lower air outlets Air will blow only from the upper outlet in the following conditions During COOL When the room temperature is close to set tempera ture When the air conditioner has operated for 2 hours During DRY operation During HE...

Страница 7: ...COOL and HEAT This ena bles you to select your preferred setting with a single push of the button ECONO COOL OPERATION Press during COOL mode page 4 to start ECONO COOL operation The unit performs swing operation vertically in various cycle according to the temperature of the unit Set temperature is set 2 C higher auto matically Press again to cancel ECONO COOL operation Pressing also cancels ECON...

Страница 8: ...closing the grille Air cleaning filter Clean every 3 months Soak the filter together with its frame in lukewarm water and wash it After cleaning dry it well in shade and put it back to its original position Install all tabs of the air filter Replace it with a new air cleaning filter every year for best perform ance Parts Number MAC 415FT E Air filter Catechin air filter Clean every 2 weeks Remove dirt b...

Страница 9: ...ing op eration makes water frozen on the outdoor unit melt and drip down White smoke is discharged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 3 Is the...

Страница 10: ...from the remote controller When using the air conditioner again 1 Clean the air filter Page 7 2 Check that the air inlet and outlet of the indoor and outdoor units are not blocked 3 Check that the earth is connected correctly To prevent the effects of a fluorescent lamp keep as far apart as possible wall etc Inverter type fluorescent lamp Keep a space to prevent the picture distortion or the noise Ra...

Страница 11: ...En 10 ...

Страница 12: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79A146H02 ...

Отзывы: