![Mitsubishi Electric Melservo-J4 MR-J4-DU*B4-RJ100 Series Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j4-mr-j4-du-b4-rj100-series/melservo-j4-mr-j4-du-b4-rj100-series_instruction-manual_240840078.webp)
76
10 APPLICATION OF FUNCTIONS
10.1 Compatible with MR-D30 functional safety unit
Connection diagram
Connecting safety controller and MR-D30
With MR-D30 used, the servo amplifier complies with safety level Category 4, PL e, SIL 3.
• Install MR-D30 in each MR-J4-DU_B4-RJ100 drive unit.
• Connect the wire for STO command (STOC) to each drive unit (the encoder master servo amplifier and each encoder slave
servo amplifier).
• To execute speed observation, use the encoder master servo amplifier. Connect the wires of the duplicated SLS1C (SLS1
command), which is outputted from the safety controller, to the encoder master servo amplifier.
• After the encoder master servo amplifier becomes STO status in the speed observation, the command is processed in the
safety controller (delayed by the input filter, input process, output process, etc.) and in the MR-D30 (taking 15 ms), and then
the encoder slave servo amplifiers become STO status.
*1 When the motor speed exceeds the observation speed, the encoder master servo amplifier becomes STO status. Make STO status of
the encoder slave servo amplifiers by the safety controller output. When STO is activated by an error in the speed observation, connect
the wires for the duplicated STOS (STO output) of the encoder master servo amplifier to the safety controller. Connect the selected
status monitor of the safety observation function (for example, SLS1S) to the safety controller. When an STOS signal of the encoder
master servo amplifier is detected, input the duplicated STOC (STO command) from the safety controller to each encoder slave servo
amplifier (and also to the encoder master servo amplifier, according to the circuit configuration).
0 V
Q1
Q2
Q3
I1
I2
I3
I4
X1
X2
I5
I6
I7
I8
24 V
0 V
Q4
A1
(24V)
A2
(0V)
FLEXB
US+
FLEXB
US+
WS0-XTIO
Application
Application
MR-J4-DU_B4-RJ100
MR-D30
Encoder
master servo
amplifier
MR-J4-DU_B4-RJ100
MR-D30
Encoder
slave servo
amplifier
MR-J4-DU_B4-RJ100
MR-D30
Encoder
slave servo
amplifier
MR-J4-DU_B4-RJ100
MR-D30
Encoder
slave servo
amplifier
24 V
Servo motor with
functional safety
STOC
SLS1C
STOS
SLS1S
WS0-CPU0
A1
(24V)
A2
(0V)
Safety controller MELSEC-WS series
CPU module WSO-CPU0
Safety I/O combined module WS0-XTIO