3 MAJOR POSITIONING CONTROL
3.2 Positioning Data Setting
LOOP
The loop control with repetition of the LOOP to LEND instructions is performed.
Operation
The loop of LOOP to LEND is repeated for the set number of the repetition.
Positioning data to be set
To use the LOOP instruction, set the following positioning data.
: Always set,
: Set as required,
: Setting not required
For details on the settings, refer to the following.
Restrictions
• If 0 is set for the number of repetition, Control method LOOP setting error (Error code: 1A33H) occurs.
• Although the error does not occur even if LEND is not set after LOOP, the repetition is not processed.
• The nesting between LOOP and LEND cannot be set. If the nesting is set, only the inner LOOP to LEND are processed
repeatedly.
The setting becomes easier than the special start FOR (times) by setting required items in the control method.
(
Page 164 Repeated start (FOR loop))
• Special start: Positioning start data, special start data, condition data, and positioning data
• Control method: Positioning data
For the special start FOR to NEXT, positioning data is required for each point of FOR and NEXT. However, the
loop is available with only one data in the control method.
The nesting is available by combining the control method LOOP to LEND and the special start FOR to NEXT.
However, LOOP to LEND cannot be set across the blocks. Set the processing of LOOP to LEND to be
finished in one block.
For details on Block, refer to the following.
Page 154 ADVANCED POSITIONING CONTROL
Setting item
Setting requirement
[Da.1]
Operation pattern
[Da.2]
Control method
(Set LOOP.)
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.5]
Axis to be interpolated
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time
[Da.10]
M code
(Sets the number of repetition.)
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed specification method
Содержание MELSEC iQ-R RD75P4
Страница 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Страница 2: ......
Страница 13: ...11 MEMO ...
Страница 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Страница 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Страница 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Страница 511: ...13 PROGRAMMING 13 4 Program Example 509 13 Torque change program Step operation program Skip program ...
Страница 512: ...510 13 PROGRAMMING 13 4 Program Example Teaching program Continuous operation interrupt program ...
Страница 513: ...13 PROGRAMMING 13 4 Program Example 511 13 Target position change program Absolute position restoration program ...
Страница 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Страница 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Страница 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Страница 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Страница 568: ...566 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Common program ...
Страница 584: ...582 APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted Restart program ...
Страница 587: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 585 A Stop program ...
Страница 597: ......