3Installing the option devices
Installing the forearm external wiring set/base external wiring set 3-89
3.6.2 Installing the base external wiring set
The installation summary of the base external wiring set is shown bellow. Mounts this option instead of the
CONBOX cover R.
Note) Although the robot's figure described to each page is RV-4FR series, the method is the same on other
robot series.
1) Loosen the fixing screws (three M4x16 screws) of CONBOX cover R and remove the box.
2) The connector: LAN, CNOP1 is in CONBOX cover R. The connector is previously attached to the connector
CNOP1. Removes this connector.
3) Connects the connector of base external wiring set to the connector of robot arm side. Connect with the
same name.
Fig.3-9 : Installing the base external wiring set (1F-HA01S-01, 1F-HA02S-01)
4) Install base external wiring set on the position where CONBOX cover R was being installed, by using original
three fixing screws. Installs carefully so that the cable etc may not be inserted.
5) Connects the cable of base external wiring set to the multifunctional electric hand, force sensor interface etc
which customer will use. The outlet and cable names of each cables are shown in
Table 3-20 : Cable to pull out and outlet
Base external
wiring set
Cable to pull out
Robot side
connection
connector
Grounding
process
Installation of
ferrite core
Outlet
Name
Purpose of use
1F-HA01S-01
<1>
E ・ F1
Multifunctional electric hand
CNOP1
Not require
Require
Force sensor interface
Require
Not require
<2>
Reserved
<3>
LAN
Vision sensor controller
LAN
Not require
Not require
<4>
RIO
Multifunctional electric hand controller
CNOP1
Not require
Require
1F-HA02S-01
<1>
E ・ F2
Force sensor interface
CNOP1
Require
Not require
<2>
E ・ F1
Multifunctional electric hand controller
CNOP1
Not require
Require
<3>
LAN
Vision sensor controller
LAN
Not require
Not require
<4>
RIO
Multifunctional electric hand controller
CNOP1
Not require
Require
CONBOX cover R
Connecting connector (two connectors)
(Inside the CONBOX cover R)
<1>
<2>
<3>
<4>
~
Customer wiring side
Cable outlet
(Refer to
Base external wiring set
LAN
CNOP1
Connectors details
CNOP1
LAN