2-19
Spare wiring
2Unpacking to Installation
2.3.2 Base area
1) Remove installation bolt and remove CONBOX cover.
CONBOX cover is completely inseparable with the robot arm.
When you install and remove the cover, be careful of the cable etc. If too much power
is applied, the robot may malfunction by the breaking of the cable.
Fig.2-10 : Pull out spare wiring(Base area)
2) Move CONBOX cover and secure the access space to spare wiring. Be careful of the cables and air hoses
which are connected into the robot arm.
3) Take out spare wiring(ADD). Spare wiring of this part is inseparable.
4) Remove the union band of spare wiring.
5) Cut spare wiring near the connector (from the connector end to the about 10-20mm. Refer to figure-A in
6) Remove the grommet of CONBOX cover. Remove the seal material which remained in the hole area of the
metal plate .
7) Remove the lock nut of attachment in the cable clamp (customer preparation).
8) Let spare wiring pass from the robot arm side of CONBOX cover in the hole after removing the grommet.
Let the lock nut pass to spare wiring previously at this time.
9) The tip area of spare wiring pass to the cable clamp. And fix with the lock nut securely.
When pulling out spare wiring, keep big power from being added to the cable, the air
hose.
Please check packing not being broken or not having stripped at the time of cover
installing and removing. Please contact the dealer, if it is broken or has stripped. If
you use it, packing broken or stripped, oil mist etc. will invade in the arm and will
cause failure.
CAUTION
CONBOX cover
Cutting position
Spare wire
ADD connector(Mele)
To inside robot arm
ADD cover
Cable clamp
Lock nut
To robot arm inside
Cut spare wiring
<figure-A>
CAUTION
CAUTION