Abnormal
Open or
short-circuit
MCFH-A24WV
80~88
Ω
44~49
Ω
35~39
Ω
43~47
Ω
13~15
Ω
14
Measure the resistance between the terminals with a tester.
(Part temperature10°C ~ 30°C)
Room
temperature
thermistor (RT11)
2. Trouble criterion of main parts
Part name
Indoor coil
thermistor (RT12)
Indoor fan
motor
(MF)
INNER FUSE
145
i
5
:
CUT OFF
Check method and criterion
Measure the resistance with a tester.
(Part temperature 10°C ~ 30°C)
Figure
Normal
8k
Ω
~ 20k
Ω
Abnormal
Open or short-circuit
Vane
motor
(MV)
Measure the resistance between the terminals with a tester.
(Part temperature10°C ~ 30°C)
Normal
Abnormal
Open or
short-circuit
328
~
356
Ω
MCFH-A12WV -
MCFH-A18WV -
MCFH-A24WV -
E1
E1
E1
BLK
RED ORN
YLW BLU BRN
WHT
GRN
YLW
FUSE
YLW
GRN
ORN
BRN
RED
ROTOR
Normal
MCFH-A18WV
WHT-BLK
MCFH-A12WV
79~87
Ω
175~190
Ω
BLK-YLW
63~69
Ω
66~72
Ω
YLW-BLU
34~38
Ω
45~50
Ω
BLU-BRN
25~29
Ω
30~33
Ω
BRN-RED
13~15
Ω
22~24
Ω
Color of lead
wire
OB336--1.qxp 04.1.6 11:13 AM Page 14