Eng-6

English

Attaching the main unit

For VL-100U

5

-E

1) Hang the catch holes on the main unit onto 

the catches of the mounting plate as shown 

below. (Both sides)

2) Press the main unit into the wall and secure 

it with the two screws provided. At this time, 

firmly press the power cord into the cut-out on 

the side of the main unit. (The unit will not sit 

snugly if the cord is not seated in the cut-out.)

Caution

 

-

Tighten the two screws securely. (The joint 

gap could cause the wall to become dirty.)

3) Insert the power plug into a wall outlet.

For VL-100EU

5

-E

1) Open the panel. Place your fingers on the 

centers of the sides of the unit and pull 

forward and up.

When opening and closing the panel, be sure 

not to stress the panel attachments.

2) Remove terminal block cover A from the main 

unit prongs.

3) Remove the screw, and then remove terminal 

block cover B.

Catch hole

Catch holes

Main unit 

mounting 

screws

Power cord

Catch

Mounting 

plate

Cut-out

(on the 

left side)

Main unit

Panel

Screw

Prong area 

on main unit

Terminal block 

cover A (plastic)

Terminal 

block cover B 

(metal)

Attaching air supply/exhaust pipes

1) Insert the air supply/exhaust pipes, which are 

attached to the pipe mounting plates, into the 

wall holes.

2) Tape the air supply/exhaust pipes tightly to 

the wall as shown below using off-the-shelf 

aluminum tape. (If the seal is not tight, the 

pipes may shift and the shutter may not 

operate properly.)

Note

 

-

Mount the air supply/exhaust pipes A so 

that the UNDER marker is at the bottom.

 

-

After mounting the pipes, check that they 

slope downward as they go outside.

 

-

When mounting the weather covers, do not 

push the air supply/exhaust pipes into the 

wall. (The shutter may not operate properly.)

Air supply side

Air supply/

exhaust pipe

Pipe mounting 

plate

Tape with 

aluminum tape 

to cover prongs 

(4 locations).

(See from front)

Pipe mounting plate
Mount the air 

supply/exhaust 

pipes A and pipe 

mounting plates 

tightly to the wall so 

they do not shift.

Aluminum tape

Apply so that it 

does not cover 

the pipe opening.

Aluminum tape

(on both air 

supply and 

exhaust sides)

Exhaust side

UNDER mark

Содержание Lossnay VL-100EU5-E

Страница 1: ...Mitsubishi Lossnay Ventilator MODEL VL 100U5 E pull cord Type VL 100EU5 E wall switch Type Installation Manual 1305875HF7701 ...

Страница 2: ...es 6 Attaching the main unit 6 Outdoor construction 8 Checks after mounting 9 Test run 9 Hazards created by mishandling and their severity are indicated by the following markers Warning This applies to mishandling or misoperation of the product which could lead to a fatal or serious injury Caution This applies to mishandling or misoperation of the product which will lead to an injury or damage to ...

Страница 3: ...sult in electric shock fire or indoor items getting wet Be sure to shut off circuit breakers or remove the power plug from the wall outlet if the Lossnay will not be used for a long period after installation Failure to do so could result in electric shock from deteriorated insulation or fire from a short circuit When attaching the main unit on the wall press the main unit against the wall and secu...

Страница 4: ...ut cardboard or the like lay the vinyl sheeting used to pack the main unit on top of it and with the main unit placed upside down as shown in the drawing remove the mounting plate The shutter of the Lossnay is closed for shipment Main unit Mounting plate Screws for securing main unit Spread cardboard or a similar material Vinyl sheeting Mounting position diagram seen from inside Unit mm 200 420 35...

Страница 5: ... wall holes away from obstructions in the wall within the ranges shown in the mounting position diagram on page 3 Wood screw fasten loosely Mounting plate Reinforcement At least 113 mm At least 83 mm At least 83 mm At least 64 mm 3 Drill the wall holes 1 Remove the loosely fastened mounting plate Leave the wood screw loosely fastened in procedure 1 in place 2 Drill the wall holes of ø85 to ø90 mm ...

Страница 6: ...haust pipe B Air supply exhaust pipe B Air supply exhaust pipe A Air supply exhaust pipe A Caulking Caulking Catch Attach under the catches Mounting plate Plumb bob Wood screw Wood screw loosely attached screw Catch Cutting air supply exhaust pipes 1 Measure the wall thickness If the wall is more than 300 mm thick use the provided air supply exhaust pipe B See page 4 section 4 for mounting instruc...

Страница 7: ...t on the left side Main unit Panel Screw Prong area on main unit Terminal block cover A plastic Terminal block cover B metal Attaching air supply exhaust pipes 1 Insert the air supply exhaust pipes which are attached to the pipe mounting plates into the wall holes 2 Tape the air supply exhaust pipes tightly to the wall as shown below using off the shelf aluminum tape If the seal is not tight the p...

Страница 8: ... unit Power connection cable pullout position Cord clamp mounting screw Ground screw Cord clamp Ground wire Operation requires a control switch Have a control switch ready and connect the wiring shown in bold on the connection diagram below Suitable cables ø0 5 to ø2 0 mm diameter Remove the covering from the final 10 mm of the power and connection cables and screw the ends in place on the termina...

Страница 9: ...in one area to ensure that the air supply and exhaust do not mix Mount the blocked parts on both the air supply and exhaust sides so that they are on the left as shown above If the weather covers shift check that the air supply exhaust pipes are cut to the correct dimensions Pushing the pipes too hard into the wall may cause the pipes to shift or prevent the shutter from operating properly Weather...

Страница 10: ...rty such as the owner or manager Checks after mounting After mounting is complete check the checklist items before doing a test run Be sure to correct any problems discovered Failure to do so will not only prevent features from operating it will also imperil your safety Checklist Check items Remedy for problem Checked Installation Is the main unit mounting strong enough Reinforce it Is the main un...

Отзывы: