7 MODBUS/RTU, ASCII (SLAVE)
7.3 Communication Setting
139
7
H1124(4388)
Menu No.
Setting
1
8
H1125(4389)
Language selection
Setting
1 (Japanese), 2 (English), 3 (Chinese)
H1126(4390)
Operation mode selection
Setting
1 (LE7-40GU), 2 (LE-40MT), 3 (LE-30CT)
H1127(4391)
Selection of function to use 1
Setting
0
0xFFFF
H1128(4392)
Selection of function to use 2
Setting
0
0xFFFF
H1129(4393)
Memory cassette backup selection
Setting
0 (backup not provided), 1 (backup
provided)
H112A(4394)
Data copy selection
Setting
0 (No function) 1 (Copy to Menu 1), 2
(Copy to Menu 2) 3 (Copy to Menu 3) 4
(Copy to Menu 4), 5 (Copy to Menu 5), 6
(Copy to Menu 6), 7 (Copy to menu 7), 8
(Copy to Menu 8), 9 (Read from memory
cassette), 10 (write to memory cassette),
11 (Check with memory cassette)
H112B(4395)
Data initialization selection
Setting
0 (no function), 1 (initialize all parameters)
H112C(4396)
H112D(4397)
H112E(4398)
H112F(4399)
H1130(4400)
Alarm history 1
Monitor
0
63
H1131(4401)
Alarm history 2
Monitor
0
63
H1132(4402)
Alarm history 3
Monitor
0
63
H1133(4403)
Alarm history 4
Monitor
0
63
H1134(4404)
Alarm history 5
Monitor
0
63
H1135(4405)
Alarm history 6
Monitor
0
63
H1136(4406)
Alarm history 7
Monitor
0
63
H1137(4407)
Alarm history 8
Monitor
0
63
H1138(4408)
Alarm history holding selection
Setting
0 (no holding), 1 (holding)
H1139(4409)
Alarm display time
Setting
0
301
sec
H113A(4410)
Alarm operation selection 1
Setting
0
0xFFFF
H113B(4411)
Alarm operation selection 2
Setting
0
0xFFFF
H113C(4412)
Alarm operation selection 3
Setting
0
0xFFFF
H113D(4413)
Alarm operation selection 4
Setting
0
0xFFFF
H113E(4414)
H113F(4415)
H1140(4416)
Network mode selection
Setting
0 (No function), 1 (N:N Network), 2
(MODBUS/RTU), 3 (MODBUS (ASCII)), 4
(CC-Link), 5 (CC-Link IEF)
H1141(4417)
Station No. in N:N Network
Setting
1
7
H1142(4418)
MODBUS station No.
Setting
1
247
H1143(4419)
MODBUS format selection
Setting
0
0xFFFF
H1144(4420)
CC-Link station No.
Setting
LE7-CCL
1
64
H1145(4421)
Number of occupied stations in CC-Link
Setting
LE7-CCL
0 (2 stations occupied), 1 (4 stations
occupied)
H1146(4422)
Communication speed in CC-Link
Setting
LE7-CCL
0 (156k), 1 (625k), 2 (2.5M), 3 (5M), 4
(10M)
H1147(4423)
CC-Link version
Setting
0 (Ver.2.00), 1 (Ver.1.10)
H1148(4424)
Extended cyclic in CC-Link
Setting
LE7-CCL
0 (1x), 1 (2x), 2 (4x)
H1149(4425)
CC-Link IE network No.
Setting
LE7-CCL
1
239
H114A(4426)
CC-Link IE station No.
Setting
1
120
H114B(4427)
H114C(4428)
H114D(4429)
H114E(4430)
H114F(4431)
Holding
register
Name
Monitor/
settings
Extension
option
Minimum value
Maximum value
Unit
Содержание LE7-40GU
Страница 1: ...LE7 40GU INSTRUCTION MANUAL Communication ...
Страница 2: ......
Страница 10: ...8 TRADEMARKS 150 ...
Страница 11: ...9 CONTENTS ...
Страница 37: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 35 3 ...
Страница 38: ...36 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Страница 39: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 37 3 ...
Страница 40: ...38 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Страница 57: ...4 SLMP COMMUNICATION 4 3 Reference Program 55 4 Program example ...
Страница 58: ...56 4 SLMP COMMUNICATION 4 3 Reference Program ...
Страница 59: ...4 SLMP COMMUNICATION 4 3 Reference Program 57 4 ...
Страница 60: ...58 4 SLMP COMMUNICATION 4 3 Reference Program ...
Страница 61: ...4 SLMP COMMUNICATION 4 3 Reference Program 59 4 ...
Страница 82: ...80 5 MODBUS TCP SLAVE 5 3 Reference Program Program example ...
Страница 83: ...5 MODBUS TCP SLAVE 5 3 Reference Program 81 5 ...
Страница 84: ...82 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Страница 85: ...5 MODBUS TCP SLAVE 5 3 Reference Program 83 5 ...
Страница 86: ...84 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Страница 110: ...108 6 N N NETWORK 6 4 Reference Program Program example ...
Страница 111: ...6 N N NETWORK 6 4 Reference Program 109 6 ...
Страница 112: ...110 6 N N NETWORK 6 4 Reference Program ...
Страница 147: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 145 7 Function code H03 Read holding register ...
Страница 149: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 147 7 ...
Страница 153: ......