6
─
4. Specifications
Model
Rated
voltage
(V)
Rated
frequency
(Hz)
Heater
Motor
speed
Rated
current
(A)
Power con-
sumption
(W)
Air
speed
(m/s)
Noise
(dB)
Weight
(kg)
Drain tank
capacity
(
ℓ
)
JT-SB216JSH2-W-NE
JT-SB216JSH2-H-NE
JT-SB216JSH2-S-NE
220-240
Single phase
50-60
ON
High 5.7-6.2
1240
106
59
11
0.8
Standard 4.9-5.3
1070
98
56
OFF
High 3.9-4.2
720
106
59
Standard 3.0-3.2
550
98
56
JT-SB216KSN2-W-NE
―
High 3.9-4.2
720
106
59
Standard 3.0-3.2
550
98
56
• Air speed is calculated from the static pressure measured by the pitot tube (at the nozzle).
• Noise is the A range value measured in an anechoic room.
(Average of the three points: 2 m from the front and both sides of the unit.)
• The heater is turned off automatically when ambient temperature reaches 32°C or more. (Applicable models: JT-
SB216JSH2-W/H/S-NE)
5. Outside dimensions
JT-SB216JSH2-W-NE, JT-SB216JSH2-H-NE, JT-SB216JSH2-S-NE, JT-SB216KSN2-W-NE
168
Terminal block
80
Installation panel
(Fix plate)
10
393
670
658
Power cable hole
(rear)
Terminal block
Drain tank
Air
¿
lter (air intake)
* Maximum width of main unit
219
2
93
189
263
267
77
68
(
79.5
)(
103.5
)
300*
Installation panel
(Fix plate)
Installation holes
Detailed view of installation holes
Unit: mm
Содержание JT-SB216JSH2-H-NE
Страница 32: ... 32 83 82 81 84 85 86 JT SB216JSH2 W NE ...
Страница 40: ... 40 JT SB216JSH2 H NE 83 82 81 84 85 86 ...
Страница 48: ... 48 JT SB216JSH2 S NE 83 82 81 84 85 86 ...
Страница 56: ... 56 JT SB216KSN2 W NE 83 82 81 84 85 86 ...