4. EMC DIRECTIVE

For the products sold in European countries, the conformance to the 

EMC Directive, which is one of the European Directives, has been a 

legal obligation since 1996. Also, conformance to the Low Voltage.

Directive, another European Directives, has been a legal obligation since 

1997.

Manufacturers who recognize their products must conform to the EMC 

and Low Voltage Directive are required to declare that their products 

conform to these Directives and put a "CE mark" on their products.

• Authorized representative in Europe

Authorized representative in Europe is shown below.

Name

:Mitsubishi Electric Europe BV

Address :Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

4.1 Requirements to Meet EMC Directive

EMC Directives are those which require "any strong electromagnetic 

force is not output to the external.:Emission (electromagnetic 

interference)" and "It is not influenced by the electromagnetic wave from 

the external.: Immunity (electromagnetic sensitivity)".

Items4.1.1 through4.1.3 summarize the precautions to use GOT and 

configure the mechanical unit in order to match the EMC directives.

Though the data described herein are produced with our best on the 
basis of the requirement items and standards of the restrictions gathered 
by Mitsubishi, they do not completely guaranteed that all mechanical unit 
manufactured according to the data do not always match the above. 

4.1.1  EMC  directiveThe  standards  of  the  EMC

Directive are shown below.

*1: The GOT is an open type device (device installed to another device) and must 

be installed in a conductive control panel.
The above test items are conducted in the condition where the GOT is installed 
on the conductive control panel and combined with the Mitsubishi PLC.

*2: When using the sound output cable, the cable length must be 30 m (1181.1 in.) 

or shorter.

*3: QP (Quasi-Peak): Quasi-peak value, Mean: Average value
*4: The above test items are conducted in the following conditions.

30 M-230 MHz QP : 40 dB V/m (10m in measurement range)
230 M-1000 MHz QP : 47 dB V/m (10m in measurement range)

Applied 

standard

Test standard

Test details

Standard value

EN61131-2
: 2007

CISPR16-2-3
Radiated noise

*1, *2

Electromagnetic 
emissions from the 
product are 
measured.

30 M-230 MHz QP:
30 dB V/m (30 m in 
measurement range)

*3, *4

230 M-1000 MHz QP:
37 dB V/m(30 m in 
measurement range)

*3, *4

IEC61000-4-2
Electrostatic 
immunity

*1, *2

Immunity test in 
which static 
electricity is applied 
to the cabinet of the 
equipment.

4 kV Contact discharge
8 kV Aerial discharge

IEC61000-4-3
Radiated 
electromagnetic 
field AM 
modulation

*1, *2

Immunity test in 
which field is 
irradiated to the 
product.

80-1000 MHz: 10 V/m
1.4-2 GHz: 3 V/m
2.0-2.7 GHz: 1 V/m
80%AM modulation@1 kHz

IEC61000-4-4
Fast transient burst 
noise

*1, *2

Immunity test in 
which burst noise is 
applied to the power 
line and signal lines.

Power line: 2 kV
Digital I/O: 1 kV
Analog I/O: 1 kV
Signal lines: 1 kV

IEC61000-4-5
Surge immunity

*1, *2

Immunity test in 
which lightening 
surge is applied to 
the product.

DC power type

Power line (between line and  
ground) :  0.5 kV

   Power line (between lines)

             :  0.5 kV

   Data communication port

             :  1 kV

IEC61000-4-6
Conducted RF 
immunity

*1, *2

Immunity test in 
which a noise 
inducted on the 
power and signal 
lines is applied.

Power line: 10 V
Data communication port: 10 V

IEC61000-4-8
Power supply 
frequency magnetic 
field immunity

*1, *2

Test for checking 
normal operations 
under the 
circumstance 
exposed to the 
ferromagnetic field 
noise of the power 
supply frequency 
(50/60 Hz).

30 A/m

4.1.2 Control panel

The GOT is an open type device (device installed to another device) and 
must be installed in a conductive control panel.
It not only assure the safety but also has a large effect to shut down the 
noise generated from GOT, on the control panel.
(1) Control Panel

(a) The control panel must be conductive.
(b) When fixing a top or bottom plate of the control panel with bolts, 

do not coat the plate and bolt surfaces so that they will come into 
contact.
And connect the door and box using a thick grounding cable in 
order to ensure the low impedance under high frequency.

(c) When using an inner plate to ensure electric conductivity with the 

control panel, do not coat the fixing bolt area of the inner plate 
and control panel to ensure conductivity in the largest area as 
possible.

(d) Ground the control panel using a thick grounding cable in order to 

ensure the low impedance under high frequency.

(e) The diameter of cable holes in the control panel must be 10 cm 

(3.94 in.). In order to reduce the chance of radio waves leaking 
out, ensure that the space between the control panel and its door 
is small as possible.
Paste the EMI gasket directly on the painted surface to seal the 
space so that the leak of electric wave can be suppressed.
Our test has been carried out on a panel having the damping 
characteristics of 37 dB max. and 30dB mean (measured by 3 m 
method with 30 to 300 MHz).

(2) Connection of power and ground wires

Ground and power supply wires for the GOT must be connected as 
described below.
(a) Provide a ground point near the GOT. Short-circuit the FG 

terminal of the GOT, and ground it with the thickest and shortest 
cable possible. (The cable length must be 30 cm (11.81 in.) or 
shorter.)
The FG terminal function is to pass the noise generated in the PC 
system to the ground, so an impedance that is as low as possible 
must be ensured. As the wires are used to relieve the noise, the 
wire itself carries a large noise content and thus short wiring 
means that the wire is prevented from acting as an antenna.
Note) A long conductor will become a more efficient antenna at 
high frequency.

(b) The earth wire led from the earthing point must be twisted with 

the power supply wires.
By twisting with the earthing wire, noise flowing from the power 
supply wires can be relieved to the earthing. However, if a filter is 
installed on the power supply wires, the wires and the earthing 
wire may not need to be twisted.

4.1.3 Noise filter (power supply line filter)

The noise filter (power supply line filter) is a device effective to reduce 
conducted noise. Except some models, installation of a noise filter onto 
the power supply lines is not necessary. However conducted noise can 
be reduced if it is installed. (The noise filter is generally effective for 
reducing conducted noise in the band of 10 MHz or less.) Usage of the 
following filters is recommended.

The precautions required when installing a noise filter are described 
below.

(1) Do not install the input and output cables of the noise filter together 

to prevent the output side noise will be inducted into the input side 
cable where noise has been eliminated by the noise filer.

(2) Connect the noise filter's ground terminal to the control panel with 

the shortest cable as possible (approx. 10 cm (3.94 in.) or less).

Model name

FN343-3/05

FN660-6/06

RSHN-2003

Manufacturer

SCHAFFNER

SCHAFFNER

TDK

Rated current

3 A

6 A

3 A

Rated voltage

250 V

• Installing the input and output cables 

together will cause noise induction.

• Separate the input cable from the output 

cable.

Filter

Induction

Output side

(device side)

Input side

(power supply side)

Filter

Output side

(device side)

Input side

(power supply side)

5. INSTALLATION

5.1 Control Panel Inside Dimensions for 

Mounting GOT

Install the GOT on the control panel out of the way for the equipment 
inside the control panel. Do not install the GOT and the unit in 
prohibited areas for the installation.

5.2 Panel Cutting Dimensions

5.3 Mounting Position

When mounting the GOT, the following clearances must be maintained 
from other structures and devices.
Some cables may need to be longer than the specified dimensions when 
connecting to the GOT.
Therefore, consider the connector dimensions and bending radius of the 
cable as well for installation.
For the lead-in allowance for cables at the bottom of the GOT, refer to 
the GOT2000 Series User’s Manual (Hardware) .
For the vertical installation, install the GOT so that the vertical installation 
arrow printed on the GOT rear face points upward.

According to the dimensions in the following table, leave clearances 
between the GOT and the other devices. The values enclosed in 
square brackets apply to the case where no other equipment 
generating radiated noise (such as a contactor) or heat is installed 
near the GOT. However, keep the ambient temperature of the GOT 
to 55 °C or lower.

                       

Unit : mm(inch)

*1:  When opening or closing the battery cover: 72(2.83) or more

Point

Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the 
GOT. Therefore, consider the connector dimensions and bending radius of the cable as 
well for installation.

Item

GT2510

GT2507

  A

51(2.01) or more

[23(0.91) or more]

64(2.52) or more

  B

Horizontal: 81(3.19) or more 

[23(0.91) or more]

Vertical: 53(2.09) or more 

[23(0.91) or more]

  C

53(2.09) or more

[23(0.91) or more]

53(2.09) or more

[32(1.26) or more]

  D

Horizontal: 53(2.09) or more 

[23(0.91) or more]

Vertical: 81(3.19) or more 

[23(0.91) or more]

  E*1

100(3.94) or more [20(0.79) or more]

Unit: mm (inch)

*Panel thickness : 1.6 to 4 mm
                          (0.06 to 0.16 inch)

GOT

A

B

GT

2507

180.5 (7.11)

+1 (0.04)
  0 (0)

133.5 (5.26)

+1 (0.04)
  0 (0)

GT

2510

243.5 (9.59)

+1 (0.04)
  0 (0)

185.5 (7.30)

+1 (0.04)
  0 (0)

B

B

Horizontal

Vertical

A

A

B

D

E

A

C

Panel thickness:

 1.6 to 4mm 

                           (0.06 to 0.16 inch)

Panel thickness: 

1.6 to 4mm 

                           (0.06 to 0.16 inch)

B

D

E

A

C

Horizontal

Vertical

5.4 Control Panel Inside Temperature and 

Installation Angle

When installing the GOT to a panel, set the display section as shown 
below.Using the GOT with the installation angle other than the following 
deteriorates the GOT earlier.
Installing the GOT horizontally

When installing the GOT with the installation angle between 60 to 

105 °, the temperature inside the control panel must be within 55 °C. 
When installing the GOT with the installation angle other than 
between 60 to 105 °, the temperature inside the control panel must be 
within 40 °C.

Installing the GOT vertically

When the GOT is installed a 90 ° angle , the control panel inside 

temperature must be within 55 °C. When the GOT is installed at any 
angle other than 90°, the control panel inside temperature must be 
within 40 °C.

          Horizontal                                          Vertical

GOT

Display section

Panel or others

105°

60°

GOT

Display section

Panel or others

90°

5. INSTALLATION

5.1 Dimensions intérieures du tableau de 

commande pour le montage du GOT

Installez le GOT sur le tableau de commande en laissant de l'espace 
pour le dispositif à l'intérieur du tableau de commande. N'installez 
pas le GOT et le module dans des zones où l'installation est interdite.

5.2 Cotes de découpe du panneau

5.3 Position de montage

Lors du montage du GOT, laissez les espaces suivants pour les autres 
structures et dispositifs.Certains câbles peuvent être plus longs que les 
dimensions spécifiées lors de la connexion au GOT.
Par conséquent, prenez également en compte les dimensions du 
connecteur et le rayon de courbure du câble pour l'installation.
Pour connaître l'espace à laisser pour les câbles sous le GOT, référez-
vous au manuel GOT2000 Series User’s Manual (Hardware).
Pour l’installation à la verticale, installez le GOT de sorte que la flèche 
d’installation à la verticale imprimée sur la face arrière du GOT pointe 
vers le haut.

 

Laissez les espaces entre le GOT et les autres dispositifs en fonction 
des dimensions contenues dans le tableau suivant. Les valeurs entre 
parenthèses s'appliquent au cas où aucun dispositif générant des 
émissions sonores (comme un contacteur) ou de la chaleur n'est installé 
près du GOT.
Toutefois, maintenez la température ambiante du GOT à 55°C ou moins.

 Unité : mm (pouce)

*1 : Pour ouvrir ou fermer le couvercle de la batterie : 72 (2,83) ou plus

Point

Câble applicable
Certains câbles peuvent être plus longs que les dimensions spécifiées lors de la 
connexion au GOT. Par conséquent, prenez également en compte les dimensions du 
connecteur et le rayon de courbure du câble pour l'installation.

Article

GT2510

GT2507

    A

51 (2,01) ou plus

[23 (0,91) ou plus]

64 (2,52) ou plus

    B

Horizontal: 81 (3,19) ou plus

[23 (0,91) ou plus]

Vertical: 53 (2,09) ou plus

[23 (0,91) ou plus]

    C

53 (2,09) ou plus

[23 (0,91) ou plus]

53 (2,09) ou plus

[32 (1,26) ou plus]

    D

Horizontal: 53 (2,09) ou plus

[23 (0,91) ou plus]

Vertical: 81 (3,19) ou plus

[23 (0,91) ou plus]

    E*1

100 (3,94) ou plus [20 (0,79) ou plus]

Unité : mm (pouce)

*Épaisseur du panneau : 1,6 à 4mm
                          (0,06 à 0,16 pouce)

GOT

A

B

GT

2507

180.5 (7.11)

+1 (0.04)
  0 (0)

133.5 (5.26)

+1 (0.04)
  0 (0)

GT

2510

243.5 (9.59)

+1 (0.04)
  0 (0)

185.5 (7.30)

+1 (0.04)
  0 (0)

B

B

Horizontal

Vertical

A

A

B

D

E

A

C

Épaisseur du panneau : 

1,6 à 4mm

(0,06 à 0,16 pouce)

Épaisseur du panneau : 

1,6 à 4mm

(0,06 à 0,16 pouce)

B

D

E

A

C

Vertical

Horizontal

5.4 Température intérieure et angle 

d'installation du tableau de commande

Lors de l'installation du GOT sur un panneau, réglez la zone d'affichage 
comme indiqué ci-dessous.
Si l'angle d'installation est différent de celui indiqué, le GOT se détériore 
plus tôt.
Installation du GOT à l’horizontale

Lors de l'installation du GOT avec un angle d'installation compris entre 
60 et 105°, la température à l'intérieur du tableau de commande doit 
être d'environ 55°C. Lors de l'installation du GOT avec un angle 
d'installation non compris entre 60 et 105°, la température à l'intérieur 
du tableau de commande doit être d'environ 40°C.

Installation du GOT à la verticale

Lors de l’installation du GOT avec un angle de 90°, la température à 
l’intérieur du panneau de commande ne doit pas dépasser 55°C. Lors 
de l’installation du GOT avec tout autre angle que 90°, la température 
à l’intérieur du panneau de commande ne doit pas dépasser 40°C.

                   Horizontal                                            Vertical

6. MAINTENANCE AND INSPECTION

Refer to the GOT2000 Series User’s Manual (Hardware)  for 
maintenance and inspection for the GOT.

GOT

Zone d'affichage

Tableau ou autres

105°

60°

90°

Zone d'affichage

GOT

Tableau ou autres

Warranty

Mitsubishi Electric will not be held liable for damage caused by 
factors found not to be the cause of Mitsubishi Electric; machine 
damage or lost profits caused by faults in the Mitsubishi Electric 
products; damage, secondary damage, accident compensation 
caused by special factors unpredictable by Mitsubishi Electric; 
damages to products other than Mitsubishi Electric products; and to 
other duties.

For safe use

• This product has been manufactured as a general-purpose part for 

general industries, and has not been designed or manufactured to 
be incorporated in a device or system used in purposes related to 
human life. 

• Before using the product for special purposes such as nuclear 

power, electric power, aerospace, medicine or passenger 
movement vehicles, consult with Mitsubishi Electric.

• This product has been manufactured under strict quality control. 

However, when installing the product where major accidents or 
losses could occur if the product fails, install appropriate backup or 
failsafe functions in the system.

USA

Brazil

Mexico

Germany

UK

Italy

Spain

France

Czech

Turkey

Poland

Russia

South Africa

China

Taiwan

Korea

Singapore

Thailand

Indonesia

Vietnam

India

Australia

Country/Region Sales office/Tel

Mitsubishi Electric Automation, Inc.
500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.
Tel: +1-847-478-2100
Mitsubishi Electric do Brasil Comercio e Servicos Ltda.
Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, 
Brasil CEP 06401-147
Tel: +55-11-4689-3000
Mitsubishi Electric Automation, Inc. Mexico Branch
Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030
Tel: +52-55-3067-7511
Mitsubishi Electric Europe B.V. German Branch
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
Tel: +49-2102-486-0
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K.
Tel: +44-1707-28-8780
Mitsubishi Electric Europe B.V. Italian Branch
Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 
Agrate Brianza (MB), Italy
Tel: +39-039-60531
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80-Apdo.420, 08190 Sant Cugat del Valles (Barcelona), Spain
Tel: +34-935-65-3131
Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, 92741 Nanterre Cedex, France
Tel: +33-1-55-68-55-68
Mitsubishi Electric Europe B.V. Czech Branch
Avenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic
Tel: +420-251-551-470
Mitsubishi Electric Turkey A.S. Umraniye Branch
Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey
Tel: +90-216-526-3990
Mitsubishi Electric Europe B.V. Polish Branch
ul. Krakowska 50, 32-083 Balice, Poland
Tel: +48-12-347-65-00
Mitsubishi Electric (Russia) LLC St. Petersburg Branch
Piskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; 
RU-195027 St. Petersburg, Russia
Tel: +7-812-633-3497
Adroit Technologies
20 Waterford Office Park, 189 Witkoppen Road, Fourways, Johannesburg, South Africa
Tel: +27-11-658-8100
Mitsubishi Electric Automation (China) Ltd.
No.1386 Hongqiao Road, Mitsubishi Electric Automation Center, Shanghai, China
Tel: +86-21-2322-3030
SETSUYO ENTERPRISE CO., LTD.
6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan
Tel: +886-2-2299-2499
Mitsubishi Electric Automation Korea Co., Ltd.
7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, 
Seoul 07528, Korea
Tel: +82-2-3660-9530
Mitsubishi Electric Asia Pte. Ltd.
307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943
Tel: +65-6473-2308
Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.
12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, 
Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand
Tel: +66-2682-6522 to 31
PT. Mitsubishi Electric Indonesia
Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia
Tel: +62-21-3192-6461
Mitsubishi Electric Vietnam Co., LTD. Ho Chi Minh Head Office
Unit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Street, District 1, 
Ho Chi Minh City, Vietnam
Tel: +84-8-3910-5945
Mitsubishi Electric India Pvt. Ltd. Pune Branch
Emerald House, EL -3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India
Tel: +91-20-2710-2000
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W. 2116, Australia
Tel: +61-2-9684-7777

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN

When exported from Japan, this manual does not require application to the Ministry 

of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.

Printed in Japan, April 2018.