57
Function (Parameter) list
2
P
ara
me
te
r L
ist
The extended function parameters are made valid by setting "1" in Pr. 30 "extended
function display selection". (For more detailed information on the way to set Pr. 30,
refer to the instruction manual (basic).)
Func-
tion
Para-
meter
Indica-
tion
Name
Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
S
tand
ar
d op
er
a
tio
n f
u
nc
tion
s
Parameters 0 to 9 are basic function parameters.
10
DC injection
brake
operation
frequency
0 to 120Hz
0.1Hz
3Hz
11
DC injection
brake
operation time
0 to 10s
0.1s
0.5s
12
DC injection
brake voltage 0 to 15%
0.1%
6%
13
Starting
frequency
0 to 60Hz
0.1Hz
0.5Hz
14
Load pattern
selection
0: For constant-torque
loads,
1: For reduced-torque
loads,
2: For vertical lift loads,
3: For vertical lift loads
1
0
15
Jog frequency 0 to 120Hz
0.1Hz
5Hz
16
Jog
acceleration/
deceleration
time
0 to 999s
0.1s
0.5s
17
RUN key
rotation
direction
selection
0: Forward rotation,
1: Reverse rotation
1
0
19
Base frequency
voltage
0 to 800V, 888, - - -
1V
- - -
20
Acceleration/
deceleration
reference
frequency
1 to 120Hz
0.1Hz
60Hz
21
Stall
prevention
function
selection
0 to 31, 100
1
0
22
Stall
prevention
operation level
0 to 200%
1%
150%
23
Stall
prevention
operation level
compensation
factor at
double speed
0 to 200%, - - -
1%
- - -
Содержание FR-S500 Series
Страница 178: ...168 MEMO ...
Страница 215: ...205 APPENDIX APPENDIX 1 Parameter instruction code list 206 ...