FUNCTION AND BASIC OPERATION
2.1.5
Changing the main monitor item from the Function menu
The monitor list is displayed when the Monitor selection in the Function menu is selected.
When a monitor item is set from the monitor list, the new monitor item is registered and displayed in the fourth monitor screen.
(For the Function menu, refer to
2.1.6
Changing the main monitor item by parameter
Using
Pr.52 Operation panel main monitor selection
, the monitor item on the third monitor screen can be changed.
However, the item on the second monitor screen is changed accordingly when "17" (load meter), "18" (motor excitation
current), or "24" (motor load factor) is set in
Pr.52
.
2.1.7
Setting of the monitor data screen at power-ON (first priority monitor)
Set the monitor screen as the first priority monitor that is displayed first at power-ON or when
is pressed.
While monitor data other than the fault history is displayed, press
to set the monitor data screen to be displayed first at
power-ON, as the first priority monitor.
NOTE
• For the details on the monitor items, refer to the Instruction Manual of the inverter.