A-1
4. Additional Instructions
Also the following points must be noted to prevent an accidental failure, injury,
electric shock, etc.
This section is specifically about safety matters
Do not attempt to install, operate, maintain or inspect the inverter until you
have read through this Installation Guideline and appended documents
carefully and can use the equipment correctly. Do not use the inverter until
you have a full knowledge of the equipment, safety information and
instructions. In this Installation Guideline, the safety instruction levels are
classified into "WARNING" and "CAUTION".
Incorrect handling may cause hazardous conditions,
resulting in death or severe injury.
Incorrect handling may cause hazardous conditions,
resulting in medium or slight injury, or may cause
only material damage.
The
level may even lead to a serious consequence according
to conditions. Both instruction levels must be followed because these are
important to personal safety.
1. Electric Shock Prevention
•
While power is on or when the inverter is running, do not open the front
cover. Otherwise you may get an electric shock.
•
Do not run the inverter with the front cover removed. Otherwise, you may
access the exposed high-voltage terminals or the charging part of the
circuitry and get an electric shock.
•
Even if power is off, do not remove the front cover except for wiring or periodic
inspection.You may access the charged inverter circuits and get an electric shock.
•
Before wiring, inspection or switching EMC filter ON/OFF connector,
power must be switched OFF. To confirm that, LED indication of the
operation panel must be checked. (It must be OFF.) Any person who is
involved in wiring, inspection or switching EMC filter ON/OFF connector
shall wait for at least 10 minutes after the power supply has been switched
OFF and check that there are no residual voltage using a tester or the like.
The capacitor is charged with high voltage for some time after power OFF,
and it is dangerous.
•
This inverter must be grounded. Grounding must conform to the
requirements of national and local safety regulations and electrical code
(NEC section 250, IEC 536 class 1 and other applicable standards).
A neutral-point grounded power supply for 400V class inverter in
compliance with EN standard must be used.
•
Any person who is involved in wiring or inspection of this equipment shall
be fully competent to do the work.
•
The inverter must be installed before wiring. Otherwise you may get an
electric shock or be injured.
•
Setting dial and key operations must be performed with dry hands to
prevent an electric shock. Otherwise you may get an electric shock.
•
Do not subject the cables to scratches, excessive stress, heavy loads or
pinching. Otherwise you may get an electric shock.
•
Do not replace the cooling fan while power is on. It is dangerous to replace
the cooling fan while power is on.
•
Do not touch the printed circuit board with wet hands. You may get an
electric shock.
•
When measuring the main circuit capacitor capacity (
Pr. 259 Main circuit
capacitor life measuring
= "1"), the DC voltage is applied to the motor for 1s
at powering off. Never touch the motor terminal, etc. right after powering
off to prevent an electric shock.
2. Fire Prevention
•
Inverter must be installed on a nonflammable wall without holes (so that
nobody touches the inverter heatsink on the rear side, etc.). Mounting it to
or near flammable material can cause a fire.
•
If the inverter has become faulty, the inverter power must be switched
OFF. A continuous flow of large current could cause a fire.
•
Do not connect a resistor directly to the DC terminals P/+ and N/-. Doing
so could cause a fire.
3. Injury Prevention
•
The voltage applied to each terminal must be the ones specified in the
Instruction Manual. Otherwise burst, damage, etc. may occur.
•
The cables must be connected to the correct terminals. Otherwise burst,
damage, etc. may occur.
•
Polarity must be correct. Otherwise burst, damage, etc. may occur.
•
While power is ON or for some time after power-OFF, do not touch the
inverter since the inverter will be extremely hot. Doing so can cause burns.
WARNING
CAUTION
CAUTION
WARNING
CAUTION
CAUTION
(1) Transportation and installation
•
The product must be transported in correct method that corresponds to
the weight. Failure to do so may lead to injuries.
•
Do not stack the boxes containing inverters higher than the number
recommended.
•
The product must be installed to the position where withstands the weight
of the product according to the information in the Instruction Manual.
•
Do not install or operate the inverter if it is damaged or has parts missing.
This can result in breakdowns.
•
When carrying the inverter, do not hold it by the front cover or setting dial;
it may fall off or fail.
•
Do not stand or rest heavy objects on the product.
•
The inverter mounting orientation must be correct.
•
Foreign conductive bodies must be prevented to enter the inverter. That
includes screws and metal fragments or other flammable substance such
as oil.
•
As the inverter is a precision instrument, do not drop or subject it to
impact.
•
The inverter must be used under the following environment: Otherwise the
inverter may be damaged.
*1 Temperature applicable for a short time, e.g. in transit.
*2 2.9m/s
2
or less for the FR-F740-04320 or more.
(2) Wiring
•
Do not install a power factor correction capacitor or surge suppressor on
the inverter output side. These devices on the inverter output side may be
overheated or burn out.
•
The connection orientation of the output cables U, V, W to the motor will
affect the direction of rotation of the motor.
(3) Test operation and adjustment
•
Before starting operation, each parameter must be confirmed and
adjusted. A failure to do so may cause some machines to make
unexpected motions.
(4) Operation
•
Any person must stay away from the equipment when the retry function is
set as it will restart suddenly after trip.
•
Since pressing
key may not stop output depending on the function
setting status, separate circuit and switch that make an emergency stop
(power OFF, mechanical brake operation for emergency stop, etc.) must
be provided.
•
OFF status of the start signal must be confirmed before resetting the
inverter fault. Resetting inverter alarm with the start signal ON restarts the
motor suddenly.
•
The inverter must be used for three-phase induction motors.
Connection of any other electrical equipment to the inverter output may
damage the equipment.
•
Do not modify the equipment.
•
Do not perform parts removal which is not instructed in this manual. Doing
so may lead to fault or damage of the inverter.
CAUTION
En
vi
ro
nme
nt
Surrounding
air
temperature
LD
-10°C to +50°C(14°F to 122°F)(non-freezing)
SLD
(initial setting) -10°C to +40°C (14°F to 104°F)(non-freezing)
Ambient humidity
90% RH or less (non-condensing)
Storage temperature
-20°C to +65°C *1 (-4°F to 149°F)
Atmosphere
Indoors (free from corrosive gas, flammable gas, oil
mist, dust and dirt)
Altitude, vibration
Maximum 1000m (3280.80feet) above sea level for
standard operation. After that derate by 3% for
every extra 500m (1640.40feet) up to 2500m
(8202feet) (92%) 5.9m/s
2
or less at 10 to 55Hz
(directions of X, Y, Z axes) *2
CAUTION
CAUTION
WARNING