![Mitsubishi Electric FR-F720-0.75K to 110K Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/mitsubishi-electric/fr-f720-0-75k-to-110k/fr-f720-0-75k-to-110k_instruction-manual_239806007.webp)
IV
4.15 Motor noise, EMI measures, mechanical resonance ................................... 158
4.15.1 PWM carrier frequency and Soft-PWM control (Pr. 72, Pr. 240, Pr. 260) ............................ 158
4.15.2 Speed smoothing control (Pr. 653, Pr. 654) ......................................................................... 159
4.16 Frequency setting by analog input (terminal 1, 2, 4) ................................... 160
4.16.1 Analog input selection (Pr. 73, Pr. 267)................................................................................ 160
4.16.2 Analog input compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)............................... 165
4.16.3 Response level of analog input and noise elimination (Pr. 74)............................................. 166
4.16.4 Bias and gain of frequency setting voltage (current)
4.17 Misoperation prevention and parameter setting restriction ....................... 172
4.17.1 Reset selection/disconnected PU detection/PU stop selection (Pr. 75) ............................... 172
4.17.2 Parameter write selection (Pr. 77) ........................................................................................ 174
4.17.3 Reverse rotation prevention selection (Pr. 78) ..................................................................... 175
4.17.4 Display of applied parameters and user group function (Pr. 160, Pr. 172 to Pr. 174) .......... 175
4.18 Selection of operation mode and operation location .................................. 177
4.18.1 Operation mode selection (Pr. 79)........................................................................................ 177
4.18.2 Operation mode at power on (Pr. 79, Pr. 340) ..................................................................... 185
4.18.3 Start command source and speed command source during
4.19.1 Wiring and configuration of PU connector ............................................................................ 191
4.19.2 Wiring and arrangement of RS-485 terminals ...................................................................... 193
4.19.3 Initial settings and specifications of RS-485 communication
4.19.4 Communication EEPROM write selection (Pr. 342) ............................................................. 197
4.19.5 Mitsubishi inverter protocol (computer link communication) ................................................. 198
4.19.6 Modbus-RTU communication specifications
4.20.1 PID control (Pr. 127 to Pr. 134, Pr. 241, Pr. 553, Pr. 554, Pr. 575 to Pr. 577,
4.20.2 Bypass-inverter switchover function (Pr. 135 to Pr. 139, Pr. 159) ........................................ 233
4.20.3 Regeneration avoidance function (Pr. 882 to Pr. 886) ......................................................... 238
4.21.1 Cooling fan operation selection (Pr. 244) ............................................................................. 240
4.21.2 Display of the life of the inverter parts (Pr. 255 to Pr .259)................................................... 241
4.21.3 Maintenance timer alarm (Pr. 503, Pr. 504) ......................................................................... 244
4.21.4 Current average value monitor signal (Pr. 555 to Pr. 557) ................................................... 245
4.21.5 Free parameter (Pr. 888, Pr. 889) ........................................................................................ 247
4.22 Setting from the parameter unit, operation panel........................................ 248