![Mitsubishi Electric FR-F720-0.75K to 110K Скачать руководство пользователя страница 327](http://html.mh-extra.com/html/mitsubishi-electric/fr-f720-0-75k-to-110k/fr-f720-0-75k-to-110k_instruction-manual_239806327.webp)
318
255
Life alarm status display
3F
BF
2
×
×
×
256
Inrush current limit circuit life display
40
C0
2
×
×
×
257
Control circuit capacitor life display
41
C1
2
×
×
×
258
Main circuit capacitor life display
42
C2
2
×
×
×
259
Main circuit capacitor life measuring
43
C3
2
{
{
{
261
Power failure stop selection
45
C5
2
{
{
{
262
Subtracted frequency at deceleration
start
46
C6
2
{
{
{
263
Subtraction starting frequency
47
C7
2
{
{
{
264
Power-failure deceleration time 1
48
C8
2
{
{
{
265
Power-failure deceleration time 2
49
C9
2
{
{
{
266
Power failure deceleration time
switchover frequency
4A
CA
2
{
{
{
267
Terminal 4 input selection
4B
CB
2
{
×
{
268
Monitor decimal digits selection
4C
CC
2
{
{
{
269
Parameter for manufacturer setting. Do not set.
299
Rotation direction detection selection
at restarting
6B
EB
2
{
{
{
300
BCD input bias
00
80
3
{
{
{
301
BCD input gain
01
81
3
{
{
{
302
BIN input bias
02
82
3
{
{
{
303
BIN input gain
03
83
3
{
{
{
304
Digital input and analog input
compensation enable/disable
selection
04
84
3
{
{
{
305
Read timing operation selection
05
85
3
{
{
{
306
Analog output signal selection
06
86
3
{
{
{
307
Setting for zero analog output
07
87
3
{
{
{
308
Setting for maximum analog output
08
88
3
{
{
{
309
Analog output signal voltage/current
switchover
09
89
3
{
{
{
310
Analog meter voltage output
selection
0A
8A
3
{
{
{
311
Setting for zero analog meter voltage
output
0B
8B
3
{
{
{
312
Setting for maximum analog meter
voltage output
0C
8C
3
{
{
{
313
DO0 output selection
0D
8D
3
{
{
{
314
DO1 output selection
0E
8E
3
{
{
{
315
DO2 output selection
0F
8F
3
{
{
{
316
DO3 output selection
10
90
3
{
{
{
317
DO4 output selection
11
91
3
{
{
{
318
DO5 output selection
12
92
3
{
{
{
319
DO6 output selection
13
93
3
{
{
{
320
RA1 output selection
14
94
3
{
{
{
321
RA2 output selection
15
95
3
{
{
{
322
RA3 output selection
16
96
3
{
{
{
323
AM0 0V adjustment
17
97
3
{
×
{
324
AM1 0mA adjustment
18
98
3
{
×
{
329
Digital input unit selection
1D
9D
3
{
×
{
331
RS-485 communication station
1F
9F
3
{
{
*3
{
*3
332
RS-485 communication speed
20
A0
3
{
{
*3
{
*3
333
RS-485 communication stop bit length
21
A1
3
{
{
*3
{
*3
Parameter
Name
Instruction Code
* 1
Parameter
Copy
*2
Parameter
Clear
*2
All Parameter
Clear
*2
Read
Write
Extended