17
PARAMETER
588
Auxiliary motor 2
stopping frequency
0 to 400Hz
0Hz
589
Auxiliary motor 3
stopping frequency
0 to 400Hz
0Hz
590
Auxiliary motor start
detection time
0 to 3600s
5s
591
Auxiliary motor stop
detection time
0 to 3600s
5s
592
Traverse function
selection
0, 1, 2
0
593
Maximum amplitude
amount
0 to 25%
10%
594
Amplitude
compensation
amount during
deceleration
0 to 50%
10%
595
Amplitude
compensation
amount during
acceleration
0 to 50%
10%
596
Amplitude
acceleration time
0.1 to 3600s
5s
597
Amplitude
deceleration time
0.1 to 3600s
5s
611
Acceleration time at
a restart
0 to 3600s,
9999
5/15s *
1
867
AM output filter
0 to 5s
0.01s
869
Current output filter
0 to 5s
0.02s
872
Input phase failure
protection selection
0, 1
0
882
Regeneration
avoidance operation
selection
0, 1
0
883
Regeneration
avoidance operation
level
300 to 800V
760VDC
884
Regeneration
avoidance at
deceleration
detection sensitivity
0 to 5
0
885
Regeneration
avoidance
compensation
frequency limit value
0 to 10Hz,
9999
6Hz
886
Regeneration
avoidance voltage
gain
0 to 200%
100%
888
Free parameter 1
0 to 9999
9999
889
Free parameter 2
0 to 9999
9999
891
Cumulative power
monitor digit shifted
times
0 to 4, 9999
9999
892
Load factor
30 to 150%
100%
893
Energy saving
monitor reference
(motor capacity)
0.1 to 55kW/
0 to 3600kW *
1
LD/SLD
value of
applied
motor
capacity
Parameters
Name
Setting Range
Initial Value
894
Control selection
during commercial
power-supply
operation
0, 1, 2, 3
0
895
Power saving rate
reference value
0, 1, 9999
9999
896
Power unit cost
0 to 500, 9999
9999
897
Power saving
monitor average time
0, 1 to 1000h,
9999
9999
898
Power saving
cumulative monitor
clear
0, 1, 10, 9999
9999
899
Operation time rate
(estimated value)
0 to 100%,
9999
9999
C0
(900)
CA terminal
calibration
⎯
⎯
C1
(901)
AM terminal
calibration
⎯
⎯
C2
(902)
Terminal 2 frequency
setting bias
frequency
0 to 400Hz
0Hz
C3
(902)
Terminal 2 frequency
setting bias
0 to 300%
0%
125
(903)
Terminal 2 frequency
setting gain
frequency
0 to 400Hz
50Hz
C4
(903)
Terminal 2 frequency
setting gain
0 to 300%
100%
C5
(904)
Terminal 4 frequency
setting bias
frequency
0 to 400Hz
0Hz
C6
(904)
Terminal 4 frequency
setting bias
0 to 300%
20%
126
(905)
Terminal 4 frequency
setting gain
frequency
0 to 400Hz
50Hz
C7
(905)
Terminal 4 frequency
setting gain
0 to 300%
100%
C8
(930)
Current output bias
signal
0 to 100%
0%
C9
(930)
Current output bias
current
0 to 100%
0%
C10
(931)
Current output gain
signal
0 to 100%
100%
C11
(931)
Current output gain
current
0 to 100%
100%
989
Parameter copy
alarm release
10/100 *
1
10/100 *
1
990
PU buzzer control
0, 1
1
991
PU contrast
adjustment
0 to 63
58
Pr.CL
Parameter clear
0, 1
0
ALLC
All parameter clear
0, 1
0
Er.CL
Alarm history clear
0, 1
0
PCPY
Parameter copy
0, 1, 2, 3
0
Parameters
Name
Setting Range
Initial Value
*1
The setting depends on capacities. (01160 or less/01800 or more)