96
(1) Point table setting
(Pr.4 to 6, Pr.24 to Pr.27, Pr.465 to Pr.478, Pr.525 to Pr.531, Pr.537, Pr.578 to Pr.591)
Assign the target position, speed, and acceleration/deceleration time to the point tables and select the tables using the
RH, RM, and RL signals.
Position commands are accepted after the home position return operation is completed. New position data are not accepted during home position return
operation.
The maximum speed does not exceed a speed equivalent to the speed command set in
Pr.1 Maximum setting
. The
Pr.2 Minimum setting
is ignored.
During position control, acceleration/deceleration pattern is always the liner acceleration/deceleration, and the
Pr.29 Acceleration/deceleration pattern selection
setting is ignored.
Even when the RT signal is input, this setting is applied to the operation (the second deceleration time is ignored).
If the acceleration/deceleration time setting is 12r/min/1s or lower, the slope of 12r/min/1s is applied to acceleration/deceleration.
531
Seventh positioning sub-function
10
0
Plus
Absolute
position
command
Independent
10
Plus
Increment
command
Independent
100
Minus
Absolute
position
command
Independent
110
Minus
Increment
command
Independent
537
Roll feed mode selection
0
0
Point table position control based on the
absolute position
1
Point table position control in the roll feed mode
578
First positioning acceleration time
5s
0.01 to 360s
Set the basis of acceleration/deceleration
time in
Pr.20 Acceleration/deceleration reference
speed
.
Set acceleration/deceleration time within the
range of "stop" to the speed change time set
in
Pr.20
.
579
First positioning deceleration time
580
Second positioning acceleration time
581
Second positioning deceleration time
582
Third positioning acceleration time
583
Third positioning deceleration time
584
Fourth positioning acceleration time
585
Fourth positioning deceleration time
586
Fifth positioning acceleration time
587
Fifth positioning deceleration time
588
Sixth positioning acceleration time
589
Sixth positioning deceleration time
590
Seventh positioning acceleration time
591
Seventh positioning deceleration time
The above parameters can be set when
Pr.160 Extended function display selection
= "0".
When a value exceeding 3000 r/min is set, the rotation speed will be limited at 3000 r/min.
Also, when an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 12000 r/min, 3.7K: 8000
r/min)
Point
table
Position data
[Before electronic gear]
Maximum
speed
Acceleration
time
Acceleration
time
Auxiliary
function
Table selection signal
Upper
Lower
RH
RM
RL
0
Home position return mode
1
Pr.466
Pr.465
Pr.4
Pr.578
Pr.579
Pr.525
2
Pr.468
Pr.467
Pr.5
Pr.580
Pr.581
Pr.526
3
Pr.470
Pr.469
Pr.6
Pr.582
Pr.583
Pr.527
4
Pr.472
Pr.471
Pr.24
Pr.584
Pr.585
Pr.528
5
Pr.474
Pr.473
Pr.25
Pr.586
Pr.587
Pr.529
6
Pr.476
Pr.475
Pr.26
Pr.588
Pr.589
Pr.530
7
Pr.478
Pr.477
Pr.27
Pr.590
Pr.591
Pr.531
Parameter
number
Name
Initial
value
Setting
range
Description
Содержание FR-E700EX
Страница 11: ...VII MEMO ...
Страница 23: ...12 MEMO ...
Страница 288: ...286 MEMO ...
Страница 302: ...300 MEMO ...
Страница 314: ...312 MEMO ...
Страница 315: ...313 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...