Parameter
Function assignment of external terminals
FR-E700 SC EC/ENE
6 - 121
6.10.3
Condition selection of function validity by second function selection signal
(RT, Pr. 155)
You can select the second function using the RT signal. For the RT signal, set "3" in any of Pr. 178 to
Pr. 184 "Input terminal function selection" to assign the function.
The second function has the following applications:
●
Switching between normal use and emergency use.
●
Switching between heavy load and light load.
●
Changing of acceleration/deceleration time by broken line acceleration/deceleration.
●
Switching of characteristic between main motor and sub motor.
Following functions that can be set as second functions:
Fig. 6-53:
Second functions connection diagram
I001145C
Fig. 6-54:
Second acceleration/deceleration time example
I001794E
Function
Parameter Number as
Refer to
Page
1st Function
2nd Function
Torque boost
Pr. 0
Pr. 46
Base frequency
Pr. 3
Pr. 47
Acceleration time
Pr. 7
Pr. 44
Deceleration time
Pr. 8
Pr. 44, Pr. 45
Electronic thermal relay function
Pr. 9
Pr. 51
Stall prevention
Pr. 22
Pr. 48
Applied motor
Pr. 71
Pr. 450
Tab. 6-29:
Functions that can be set as second functions
NOTES
When the RT signal is on, the above second function is selected at the same time.
Changing the terminal assignment using Pr. 178 to Pr. 184 "Input terminal function selection" may
affect the other functions. Make setting after confirming the function of each terminal.
Start
Second functions selection
High speed
Middle speed
Inverter
Output fr
equenc
y
Acceleration time
is reflected
Time
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......