External operation
Basic settings
5 - 38
5.3.4 Change the frequency (40 Hz) of the maximum value of potentiometer (at 5 V)
쑶
Example
쑴
The frequency of the maximum analog voltage of the potentiometer (at 5 V) has to be changed
from the initial setting of 50 Hz to 40 Hz. Set 40 Hz in Pr. 125.
I001780E
Fig. 5-28:
Change the frequency of the maximum analog value
NOTES
Set the frequency at 0 V using calibration parameter C2.
As other adjustment methods of frequency setting voltage gain, there are methods to adjust with
a voltage applied to across terminals 2-5 and adjust at any point without a voltage applied. (Refer
to section 6.16.3 for the setting method of calibration parameter C4.)
햲
Turn the digital dial until P.125 (Pr. 125) appears.
햳
Press the SET key to show the currently set value.
The initial value "50.00" (50.00 Hz) appears.
햴
Turn the digital dial to change the set value to
"40.00" (40.00 Hz).
햵
Press the SET key to set.
햶
Press the MODE key twice to choose monitor/
frequency monitor.
햷
Turn the start switch (STF or STR) on and turn the
volume (frequency setting potentiometer)
clockwise to full slowly. (Refer to Fig. 5-27,
step
햳
to
햶
).
Operation
Display
Flicker ... 40Hz output at 5V
input complete!
Gain
Pr. 125
Initial value
Bias
C2 (Pr. 902)
50 Hz
Output fr
equenc
y [H
z]
Frequency setting signal
0
0
0
C3 (Pr. 902)
100%
5 V
10 V
C4 (Pr. 903)
Содержание fr-e700 series
Страница 2: ......
Страница 4: ......
Страница 20: ...Contents XVI ...
Страница 112: ...Operation panel Operation 4 20 ...
Страница 154: ...External operation Basic settings 5 42 ...
Страница 528: ...CC Link IE Field Network Basic Parameter 6 374 ...
Страница 562: ...Meters and measuring methods Troubleshooting 7 34 ...
Страница 606: ...A 30 Index Appendix ...
Страница 607: ......