64
PARAMETER DEFINITIONS—PPO Non Support Specification
Alarm History (IND = 0101
H
, PP = 01, SEV_II, Block II)
The past eight inverter alarm definitions can be read.
*1 Writing a value of 0000
H
to this parameter resets alarm history buffer for all alarms. All other parameters at this
index are read only.
•
Error numbers
* Refer to the inverter manual for details of the error definitions.
IND
PNU
Item
IND
PNU
Item
0101
H
0
H
Error history No. 1 read *1
0101
H
4
H
Error history No. 5 read
0101
H
1
H
Error history No. 2 read
0101
H
5
H
Error history No. 6 read
0101
H
2
H
Error history No. 3 read
0101
H
6
H
Error history No. 7 read
0101
H
3
H
Error history No. 4 read
0101
H
7
H
Error history No. 8 read
Error Number
Definition
Error Number
Definition
Error Number
Definition
00
H
No alarm
31
H
E.THM
B0
H
E.PE
10
H
E.OC1
40
H
E.FIN
B1
H
E.PUE
11
H
E.OC2
60
H
E.OLT
B2
H
E.RET
12
H
E.OC3
70
H
E.BE
C0
H
E.CPU
20
H
E.OV1
80
H
E.GF
F3
H
E. 3
21
H
E.OV2
81
H
E.LF
F6
H
E. 6
22
H
E.OV3
90
H
E.OHT
F7
H
E. 7
30
H
E.THT
A0
H
E.OPT