193
Communication operation and setting
Reply data from the drive unit to the computer 3) (With data error)
Data reading format
Communication request data from the computer to the drive unit 1)
Reply data from the drive unit to the computer 3) (No data error detected)
Reply data from the drive unit to the computer 3) (With data error)
Send data from the computer to the drive unit 5)
Format
Number of Characters
1
2
3
4
5
D
NAK
Drive unit
station
number
Error
code
Indicate a control code
Specify the drive unit station numbers between H00 and H1F (stations 0 to 31) in hexadecimal.
Set waiting time. When the
Pr. 123 PU communication waiting time setting
is other than "9999", create the communication request data without "waiting time"
in the data format. (The number of characters decreases by 1.)
CR, LF code
When data is transmitted from the computer to the drive unit, codes CR (carriage return) and LF (line feed) are automatically set at the end of a data
group on some computers. In this case, setting must also be made on the drive unit according to the computer. Whether the CR and LF codes will be
present or absent can be selected using
Pr. 124 PU communication CR/LF selection
.
Format
Number of Characters
1
2
3
4
5
6
7
8
9
B
ENQ
Drive unit
station number
Instruction code
Sum
check
Format
Number of Characters
1
2
3
4
5
6
7
8
9
10
11
12
13
E
STX
Drive unit
station number
Read data
ETX
Sum
check
E1
STX
Drive unit
station number
Read data
ETX
Sum
check
E2
STX
Drive unit
station number
Read data
ETX
Sum
check
Format
Number of Characters
1
2
3
4 to 23
24
25
26
27
E3
STX
Drive unit
station number
Read data (Drive unit model information)
ETX
Sum
check
Format
Number of Characters
1
2
3
4
5
D
NAK
Drive unit
station number
Error
code
Format
Number of Characters
1
2
3
4
C
(Without
data error)
ACK
Drive unit
station number
F
(With data
error)
NAK
Drive unit
station number
Indicate a control code
Specify the drive unit station numbers between H00 and H1F (stations 0 to 31) in hexadecimal.
Set waiting time. When the
Pr. 123 PU communication waiting time setting
is other than 9999, create the communication request data without "waiting time"
in the data format. (The number of characters decreases by 1.)
CR, LF code
When data is transmitted from the computer to the drive unit, codes CR (carriage return) and LF (line feed) are automatically set at the end of a data
group on some computers. In this case, setting must also be made on the drive unit according to the computer. Whether the CR and LF codes will be
present or absent can be selected using
Pr. 124 PU communication CR/LF selection
.
Содержание FR-D720-0.2K-G