99
Setting of acceleration/deceleration time and acceleration/ deceleration pattern
4.8.2
Minimum motor rotation speed (Pr. 13)
The above parameters can be set when
Pr. 160 Extended function display selection
= "0".
The value left of the slash is for the 2.2K drive unit or lower. The one right of the slash is for the 3.7K drive unit.
If a value exceeding the upper speed limit of the motor is set, the actual operation will be limited at the maximum rotation speed. The setting range is for the
S-PM motor. The maximum setting value differs depending on the number of poles of the applied motor.
Set the speed where the motor starts running.
Set the deadband in the low-speed range to eliminate noise and offset deviation when setting a speed with analog input.
Parameter
Number
Name
Initial Value
Setting Range
Description
13
Starting speed
15r/min
0 to 1800r/min /
0 to 1200
r/min
The speed where the motor starts
running.
The speed where the PM motor starts running can be set.
While the speed command is less than the
Pr. 13 Starting speed
setting, the PM motor is stopped.
When the speed command reaches the
Pr. 13
setting or higher,
the PM motor accelerates according to the
Pr. 7
Acceleration time
setting.
CAUTION
Note that when
Pr. 13
is set to any value lower than
Pr. 2 Minimum setting
, simply turning ON the start signal
will run the motor at the preset speed even if the command speed is not input.
Parameters referred to
Pr. 2 Minimum setting
Pr. 7 Acceleration time
Rotation speed
(r/min)
Set
speed
Rotation speed
*
* Output from 1r/min
Time
1800/1200
Setting
range
Forward rotation
ON
0
Pr. 13
Содержание FR-D720-0.2K-G
Страница 45: ...34 MEMO ...
Страница 293: ...290 MEMO ...
Страница 294: ...291 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...