![Mitsubishi Electric FR-D700 Series Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/mitsubishi-electric/fr-d700-series/fr-d700-series_installation-manuallines_239214016.webp)
13
PARAMETER LIST
6 PARAMETER LIST
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel. For details of parameters, refer to the instruction manual.
In the initial setting, only the simple mode parameters are displayed.
Set
Pr. 160 Extended function display selection
as required.
Parameter
Name
Initial
Value
Setting
Range
Remarks
160
Extended function
display selection
9999
9999
Only the simple mode parameters can be displayed.
0
Simple mode and extended mode parameters can be
displayed.
REMARKS
y
indicates simple mode parameters.
y
The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in
Pr. 77 Parameter write selection
.
Parameter
Name
Setting
Range
Initial
Value
0
Torque boost
0 to 30%
6/4/3%
∗1
1
Maximum frequency
0 to 120Hz
120Hz
2
Minimum frequency
0 to 120Hz
0Hz
3
Base frequency
0 to 400Hz
50Hz
4
Multi-speed setting (high
speed)
0 to 400Hz
50Hz
5
Multi-speed setting (middle
speed)
0 to 400Hz
30Hz
6
Multi-speed setting (low
speed)
0 to 400Hz
10Hz
7
Acceleration time
0 to 3600s
5/10s
∗2
8
Deceleration time
0 to 3600s
5/10s
∗2
9
Electronic thermal O/L relay
0 to 500A
Rated
inverter
current
10
DC injection brake operation
frequency
0 to 120Hz
3Hz
11
DC injection brake operation
time
0 to 10s
0.5s
12
DC injection brake operation
voltage
0 to 30%
6/4%
∗3
13
Starting frequency
0 to 60Hz
0.5Hz
14
Load pattern selection
0 to 3
0
15
Jog frequency
0 to 400Hz
5Hz
16
Jog acceleration/deceleration
time
0 to 3600s
0.5s
17
MRS input selection
0, 2, 4
0
18
High speed maximum
frequency
120 to 400Hz
120Hz
19
Base frequency voltage
0 to 1000V,
8888, 9999
8888
20
Acceleration/deceleration
reference frequency
1 to 400Hz
50Hz
22
Stall prevention operation level 0 to 200%
150%
23
Stall prevention operation level
compensation factor at double
speed
0 to 200%,
9999
9999
24
Multi-speed setting (speed 4)
0 to 400Hz,
9999
9999
25
Multi-speed setting (speed 5)
0 to 400Hz,
9999
9999
26
Multi-speed setting (speed 6)
0 to 400Hz,
9999
9999
27
Multi-speed setting (speed 7)
0 to 400Hz,
9999
9999
29
Acceleration/deceleration
pattern selection
0, 1, 2
0
30
Regenerative function
selection
0, 1, 2
0
31
Frequency jump 1A
0 to 400Hz,
9999
9999
32
Frequency jump 1B
0 to 400Hz,
9999
9999
33
Frequency jump 2A
0 to 400Hz,
9999
9999
34
Frequency jump 2B
0 to 400Hz,
9999
9999
35
Frequency jump 3A
0 to 400Hz,
9999
9999
36
Frequency jump 3B
0 to 400Hz,
9999
9999
37
Speed display
0, 0.01 to
9998
0
40
RUN key rotation direction
selection
0, 1
0
41
Up-to-frequency sensitivity
0 to 100%
10%
42
Output frequency detection
0 to 400Hz
6Hz
43
Output frequency detection for
reverse rotation
0 to 400Hz,
9999
9999
44
Second acceleration/
deceleration time
0 to 3600s
5/10s
∗2
Parameter
Name
Setting
Range
Initial
Value
D700_EC_Guideline_ib0600352ENG.book 13 ページ 2008年4月10日 木曜日 午後2時6分