PPO TYPE NON-SUPPORT SPECIFICATION
83
8
Operation mode read/write
Read/write of the operation mode can be performed from the master.
Set frequency read/write
The frequency set to the inverter can be read/written from the master.
Writing to PNU = HD or PNU = HE can be read out from PNU = HD.
To change the running frequency consecutively, always write data to the inverter RAM.
Terminal input read
The analog input values of terminals 2, 4, and 1 can be read.
IND
PNU
Item
Data definition
H0100
HB
Operation mode
External operation mode : H10
PU operation mode : H11 (When
Pr.79
= "6")
Network operation mode : H14
IND
PNU
Item
Data definition
H0100
HD
Set frequency (RAM) is read or written.
H0100
HE
Set frequency (EEPROM)
Write set frequency to EEPROM.
IND
PNU
Item
Minimum
setting
increments
H0100
HF
Terminal 2 input value read
0.1%
H0100
H10
Terminal 4 input value read
0.1%
H0100
H11
Terminal 1 input value read
0.1%