7
WIRING
FM type
For footnotes *1 to *15 refer to next page.
MCCB
R/L1
S/L2
T/L3
R1/L11
S1/L21
PC
10E(+10V)
10(+5V)
2
2
3
1
1
4
F/C
(FM)
SD
C1
B1
A1
U
V
W
P1
+
-
(-)
(+)
AM
5
MC
C2
B2
A2
M
TXD+
TXD-
RXD+
RXD-
GND
(SG)
SINK
SOURCE
STF
STR
STP(STOP)
RH
RM
RL
JOG
RT
MRS
RES
AU
CS
SD
RUN
SU
IPF
OL
FU
SE
(+)
(-)
5
ON
OFF
+24
SD
VCC
(+)
(-)
R
R
PX
PR
N/-
P/+
ON
4
2
OFF
(SO)
SOC
S1
S2
PC
SD
SIC
P1
R
P3
PR
N/-
P/+
So
24V
24V
Sink logic
Main circuit terminal
Control circuit terminal
Jumper
Earth
Earth (Ground)
3-phase
AC power
supply
EMC filter
ON/OFF
connector
Main circuit
Control circuit
Control input signals
Forward rotation start
Reverse rotation start
Start self-holding selection
High speed
Middle speed
Low speed
Multi-speed
selection
Jog operation
Second function selection
Output stop
Reset
Terminal 4 input selection
(Current input selection)
Selection of automatic restart
after instantaneous power
failure
Safety stop signal
24 V DC power supply
(Common for external power supply
transistor)
Frequency setting signals (Analog)
Auxiliary input
Terminal 4 input
(Current input)
0 to 5 V DC
0 to ±10 V DC
4 to 20 mA DC
0 to 10 V DC
4 to 20 mA DC
0 to ±5 V DC
0 to 5 V DC
0 to 10 V DC
Connector for plug-in option
connection
Connector 1
Terminat
-
ing
resistor
Relay output 1 (Alarm output)
Relay output 2
Running
Instantaneous power failure
Up to frequency
Overload
Frequency detection
Open collector output common
Sink/source common
Indicator
(Frequency meter, etc.)
Analog signal output
(0 to ±10 V DC)
RS-485 terminals
*14
Data transmission
Data reception
Frequency setting
potentiometer
½ W, 1 k
Inrush current
limit circuit
Open collector output
*11
Relay output
*10
Voltage/current
input switch
(Analog common)
Jumper
Brake unit
(option)
FR-A820-00770(15K)-R2R–01250(22K)-R2R
FR-A840-00470(18.5K)-R2R–01800(55K)-R2R
Motor
Earth
DC reactor
(FR-HEL)
*1
DC reactor
(FR-HEL)
*1
Brake resistor
*8
Brake unit
(option)
Moving coil type
1 mA full-scale
Earth
(Ground)
24 V external power supply
input
Common terminal
Connector 3
Shorting
wire
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
Output
shutoff
circuit
Initial value
Initial value
selectable
Initial
value
selectable
selectable
GND
Safety monitor output
Safety monitor output common
5 V (Permissible load
current 100 mA)
Brake resistor
(FR-ABR)
*7,*8
Jumper
*2
Contact input common
Calibration
resistor
*13
*12
*9
Inrush
current
limit circuit
Jumper
*5
*5
*5
*5
*4
Connector 2
*15
Ethernet
connec
-
tor
*15
PU
connec
-
tor
USB A
connec
-
tor
USB
mini B
connec
-
tor
(No voltage input allowed)
*3