17
EXTENSION ANALOG OUTPUT
4
4.4 Extension Analog Output Function Parameter List
Parameter
Number
Name
Setting Range
Minimum
Increments
Initial
Value
306
Analog output signal selection
1 to 3, 5, 7 to 12,
14, 21, 24, 52,
53, 61, 62
1
2
307
Setting for zero analog output
0 to 100%
0.1
0%
308
Setting for maximum analog output
0 to 100%
0.1
100%
309
Analog output signal voltage/current switchover
0, 1, 10, 11
1
0
310
Analog meter voltage output selection
1 to 3, 5, 7 to 12,
14, 21, 24, 52,
53, 61, 62
1
2
311
Setting for zero analog meter voltage output
0 to 100%
0.1
0%
312
Setting for maximum analog meter voltage output
0 to 100%
0.1
100%
323
AM0 0V adjustment
900 to 1100%
1
1000%
324
AM1 0mA adjustment
900 to 1100%
1
1000%
C0(900)
FM terminal calibration
⎯
⎯
⎯
C1(901)
AM terminal calibration
⎯
⎯
⎯
REMARKS
• For
Pr. 306
and
Pr. 310
, write is enabled even when the inverter is operating.