3. INVERTER SETTING
3.1 List of Dedicated Communication Parameters
When this option unit is mounted, extended functions of the following
parameters become available.
Perform setting as required.
FR-A500/F500 series parameter
*1 Pr. 500 to Pr. 502 are available only with the FR-A500 series.
Refer to the inverter manual for the availability of the parameters.
FR-V500 series parameter
Parameter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
to
page
338
Operation control
command source
0, 1
1
0
339
Speed command source
0, 1
1
0
340
Link startup mode
selection
0 to 2
1
0
500
(*1)
Communication error
recognition waiting time
0 to
999.8s
0.1s
0
501
(*1)
Communication error
occurrence count display
0
1
0
502
(*1)
Communication error-time
stop mode selection
0 to 2
1
0
Parameter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
to
page
338
Operation control
command source
0, 1
1
0
339
Speed command source
0, 1
1
0
340
Link startup mode
selection
0 to 2
1
0
400
DI11 terminal function
selection
0 to 3, 5,
8 to 12,
14 to 16, 20,
22 to 27,
42 to 44,
9999
1
9999
—
401
DI12 terminal function
selection
402
DI13 terminal function
selection
500
Communication error
recognition waiting time
0 to 999.8s
0.1s
0
501
Communication error
occurrence count display
0
1
0
502
Communication error-time
stop mode selection
0 to 2
1
0