FR-A5NP Profibus DP
Communications Option Unit
37
Pr280 118h Brake Openg Current Detect Time
0-2
0-14
0.1s
0.1s
Pr281 119h Brake Op Time At Start
0-5
0-32
0.1s
0.1s
Pr282 11Ah Brake Closg Frequency
0-30
0-BB8
0.01Hz
0.01Hz
Pr293 11Bh Brake Op Time At Stop
0-5
0-32
0.1s
0.1s
Pr284 11Ch Dec Detectn Func Selectn
0-1
0-1
1
1
Pr285 11Dh Overspd Detectn Frequency
0-30
0-BB8
0.01Hz
0.01Hz
Pr330 11Eh Special
Pr331 11Fh Special
Pr332 120h Special
Pr333 121h Special
Pr334 122h Special
Pr335 123h Special
Pr336 124h Special
Pr337 125h Special
Pr338 126h Op Cmd Source
0-1
0-1
1
1
Pr339 127h Spd Cmd Source
0-1
0-1
1
1
Pr340 128h Link Startup Mode Selectn
0-2
0-2
1
1
Pr341 129h Special
Pr342 12Ah Special
Pr360 13Ch Special
Pr361 13Dh Special
Pr362 13Eh Special
Pr363 13Fh Special
Pr364 140h Special
Pr365 141h Special
Pr366 142h Special
Pr367 143h Special
Pr368 144h Special
Notes:
1. Some default values depend on the size of the VFD.
2. 65535, 6553.5Unit, 655.35 Unit simply indicate the function is NOT
active, its meaning is the same as 9999 on PU, or in the FR-A500(L)
Manual.
3. Please refer to Mitsubishi FR-A500(L) Instruction Manual for more
details.
Para PNU
Definition
Range Hex
A500
A500L
Содержание FR-A 500
Страница 50: ...50 3 Setting Inputs Note Bold indicates byte swapping code required for ladder logic using AISJ71PB92 module ...
Страница 51: ...FR A5NP Profibus DP Communications Option Unit 51 ...
Страница 52: ...52 ...
Страница 54: ...54 ...
Страница 56: ...56 ...
Страница 63: ...FR A5NP Profibus DP Communications Option Unit 63 ...
Страница 64: ...64 ...
Страница 65: ...FR A5NP Profibus DP Communications Option Unit 65 ...