FR-A5NP Profibus DP
Communications Option Unit
31
6.3. IND = 0200h, Normal Parameter Area
Para PNU
Definition
Range Hex
A500
A500L
Pr0
0h
Torque Boost (Manual)
0-30
0-12C
0.1%
0.1%
Pr1
1h
Max frequency Limit
0-120
0-2EE0
0.01Hz
0.01Hz
Pr2
2h
Min frequency Limit
0-120
0-2EE0
0.01Hz
0.01Hz
Pr3
3h
Base frequency Limit
0-400
0-9C40
0.01Hz
0.01Hz
Pr4
4h
MultiSpeed Set (HiSpeed)
0-400
0-9C40
0.01Hz
0.01Hz
Pr5
5h
MultiSpeed Set (MiSpeed)
0-400
0-9C40
0.01Hz
0.01Hz
Pr6
6h
MultiSpeed Set (LoSpeed)
0-400
0-9C40
0.01Hz
0.01Hz
Pr7
7h
Acc t
0-3600/ 0-8CA0
0.1s/
0.1s/
0-360
0.01s
0.01s
Pr8
8h
Dec t
0-3600/ 0-8CA0
0.1s/
0.1s/
0-360
0.01s
0.01s
Pr9
9h
Electr Therml O/L Relay
0-500
0-C350
0.01A
0.1A
Pr10 Ah
DC Inj Brake Op f
0-120
0-2EE0
0.01Hz
0.01Hz
Pr11 Bh
DC Inj Brake Op t
0-10
0-64
0.1s
0.1s
Pr12 Ch
DC Inj Brake V
0-30
0-12C
0.1%
0.1%
Pr13 Dh
Startg frequency
0-60
0-1770
0.01Hz
0.01Hz
Pr14 Eh
Applied Load Pattern
0-5
0-5
1
1
Pr15 Fh
Jog frequency
0-400
0-9C40
0.01Hz
0.01Hz
Pr16 10h
Jog Acc/Dec t
0-3600/ 0-8CA0
0.1s/
0.1s/
0-360
0.01s
0.01s
Pr17 11h
MRS Input Selection
0-2
0-2
1
1
Pr18 12h
HiSpeed Max frequency Limit
120-400 2EE0-9C40 0.01Hz
0.01Hz
Pr19 13h
Base frequency V
0-1000 0-2710
0.1V
0.1V
Pr20 14h
Acc/Dec Ref frequency
0-400
0-9C40
0.01Hz
0.01Hz
Pr21 15h
Acc/Dec time Increments
0-1
0-1
1
1
Pr22 16h
Pr22 Stall Prevention Op Level
0-200
0-7D0
0.1%
0.1%
Pr23 17h
Stall Prevention Op Level At DoubleSpeed 0-200
0-7D0
0.1%
0.1%
Pr24 18h
MultiSpeed Set (Speed4)
0-400
0-9C40
0.01Hz
0.01Hz
Pr25 19h
MultiSpeed Set (Speed5)
0-400
0-9C40
0.01Hz
0.01Hz
Pr26 1Ah
MultiSpeed Set (Speed6)
0-400
0-9C40
0.01Hz
0.01Hz
Pr27 1Bh
MultiSpeed Set (Speed7)
0-400
0-9C40
0.01Hz
0.01Hz
Pr28 1Ch
MultiSpeed Input Compensation
0-1
0-1
1
1
Pr29 1Dh
Acc/Dec Pattern
0-3
0-3
1
1
Pr30 1Eh
Regen Brake Duty Change
0-2
0-2
1
1
Pr31 1Fh
Frequency Jump 1A
0-400
0-9C40
0.01Hz
0.01Hz
Pr32 20h
Frequency Jump 1B
0-400
0-9C40
0.01Hz
0.01Hz
Pr33 21h
Frequency Jump 2A
0-400
0-9C40
0.01Hz
0.01Hz
Pr34 22h
Frequency Jump 2B
0-400
0-9C40
0.01Hz
0.01Hz
Pr35 23h
Frequency Jump 3A
0-400
0-9C40
0.01Hz
0.01Hz
Pr36 24h
Frequency Jump 3B
0-400
0-9C40
0.01Hz
0.01Hz
Pr37 25h
Speed Display
0-9998 0-270E
1
1
Pr38 26h
Special
Pr39 27h
Special
Содержание FR-A 500
Страница 50: ...50 3 Setting Inputs Note Bold indicates byte swapping code required for ladder logic using AISJ71PB92 module ...
Страница 51: ...FR A5NP Profibus DP Communications Option Unit 51 ...
Страница 52: ...52 ...
Страница 54: ...54 ...
Страница 56: ...56 ...
Страница 63: ...FR A5NP Profibus DP Communications Option Unit 63 ...
Страница 64: ...64 ...
Страница 65: ...FR A5NP Profibus DP Communications Option Unit 65 ...