When installing or relocating the unit, check
that no substance other than the specified
refrigerant (R410A) enters the refrigerant circuit.

¡

Any presence of foreign substance or air can cause abnormal
pressure rise or explosion.

¡

For your safety, thoroughly read the following instructions prior to installation.

Safety Precautions

¡

Thoroughly read the following “Safety Precautions” to ensure proper installation.

¡

Observe the following important safety precautions at all times.

¡

Hazards that can occur from incorrect handling are classified by the symbols below:

Mitsubishi Electric Air Conditioner CITY MULTI

Twinning Kit Installation Manual

WARNING

CAUTION

WARNING

Incorrect handling can result in death or serious injury.

Incorrect handling can result in bodily injury and/or structure damage.

See the Installation Manual that came with the outdoor unit for installation instructions.

CAUTION

Only a dealer or qualified technician should
perform installation.

¡

Improper installation may result in refrigerant gas leakage
and equipment damage.

Do not make any modifications or alterations.
Consult your dealer for repair.

¡

Improper installation may result in water leakage, electric shock,
or fire.

In the event of a refrigerant leak, thoroughly
ventilate the room.

¡

If refrigerant leaks and comes in contact with an open flame,
toxic gases will be generated.

Properly install all parts according to the
instructions in the Installation Manual.

¡

If the wrong twinning pipe or wrong size connecting pipe is
used, air conditioning performance will suffer.

After installation, check for a refrigerant leak.

¡

If leaked refrigerant comes in contact with a heat source,

such as a fan heater, stove, or electric grill, toxic gases will be
generated. 

Properly dispose of packing materials.

¡

Plastic bags can pose suffocation and choking hazards: keep
them out of the reach of children. Tear the plastics bags
before disposing of them.

Do not touch the refrigerant pipes and
refrigerant circuit components with bare
hands during and immediately after operation.

¡

During or immediately after operation, certain parts of the unit
such as pipes and compressor may be either very cold or hot,
depending on the state of the refrigerant in the unit at the
time. To reduce the risk of frostbites and burns, do not touch
these parts with bare hands.

1

CMY-R100VBK, CMY-R200VBK

WT05221X02

Содержание CMY-R100VBK

Страница 1: ...r alterations Consult your dealer for repair Improper installation may result in water leakage electric shock or fire In the event of a refrigerant leak thoroughly ventilate the room If refrigerant leaks and comes in contact with an open flame toxic gases will be generated Properly install all parts according to the instructions in the Installation Manual If the wrong twinning pipe or wrong size c...

Страница 2: ...P72 P96 P96 P120 D0 CMY R100VBK CMY R200VBK CMY R100VBK CMY R100VBK CMY R100VBK F0 Twinning pipe Outdoor unit Low pressure E or F A3 B3 C3 D3 E3 PURY YHM PURY YHMU PURY THMU A1 A2 A3 P200 Ø15 88 Ø19 05 EP200 Ø15 88 Ø19 05 P72 Ø15 88 Ø19 05 P72 Ø15 88 Ø19 05 B1 B2 B3 P250 Ø19 05 Ø22 2 EP300 Ø19 05 Ø22 2 P96 Ø19 05 Ø22 2 P96 Ø19 05 Ø22 2 C1 C2 C3 P300 Ø19 05 Ø22 2 A P120 Ø19 05 Ø28 58 P120 Ø19 05 Ø2...

Страница 3: ...e cover and attach compressor cables to item 9 pipe cover with item M cable tie to keep them out of direct contact with the pipes 1 3 5 6 Field supplied pipes Field supplied pipes Connect the pipe so that the dimples on the 7 high pressure pipe are on an imaginary line parallel to the edge of the cutout hole 9 Wrap the pipe cover here Attach compressor cables to Pipe cover with Cable tie to keep t...

Страница 4: ... 2High pressure twinning pipe LInsulation cover Tape field supplied To be gap free To be gap free 4 See reverse 3 Pipe Connection Example Connect the pipes between outdoor units using the figure below as a reference Main low pressure pipe field supplied Main high pressure pipe field supplied 2High pressure twinning pipe Low pressure connecting pipe field supplied High pressure connecting pipe fiel...

Отзывы: