background image

When installing or relocating the unit, check
that no substance other than the specified
refrigerant (R410A) enters the refrigerant circuit.

¡

Any presence of foreign substance or air can cause abnormal
pressure rise or explosion.

¡

For your safety, thoroughly read the following instructions prior to installation.

Safety Precautions

¡

Thoroughly read the following “Safety Precautions” to ensure proper installation.

¡

Observe the following important safety precautions at all times.

¡

Hazards that can occur from incorrect handling are classified by the symbols below:

Mitsubishi Electric Air Conditioner CITY MULTI

Twinning Kit Installation Manual

WARNING

CAUTION

WARNING

Incorrect handling can result in death or serious injury.

Incorrect handling can result in bodily injury and/or structure damage.

See the Installation Manual that came with the outdoor unit for installation instructions.

CAUTION

Only a dealer or qualified technician should
perform installation.

¡

Improper installation may result in refrigerant gas leakage
and equipment damage.

Do not make any modifications or alterations.
Consult your dealer for repair.

¡

Improper installation may result in water leakage, electric shock,
or fire.

In the event of a refrigerant leak, thoroughly
ventilate the room.

¡

If refrigerant leaks and comes in contact with an open flame,
toxic gases will be generated.

Properly install all parts according to the
instructions in the Installation Manual.

¡

If the wrong twinning pipe or wrong size connecting pipe is
used, air conditioning performance will suffer.

After installation, check for a refrigerant leak.

¡

If leaked refrigerant comes in contact with a heat source,

such as a fan heater, stove, or electric grill, toxic gases will be
generated. 

Properly dispose of packing materials.

¡

Plastic bags can pose suffocation and choking hazards: keep
them out of the reach of children. Tear the plastics bags
before disposing of them.

Do not touch the refrigerant pipes and
refrigerant circuit components with bare
hands during and immediately after operation.

¡

During or immediately after operation, certain parts of the unit
such as pipes and compressor may be either very cold or hot,
depending on the state of the refrigerant in the unit at the
time. To reduce the risk of frostbites and burns, do not touch
these parts with bare hands.

1

CMY-Q100VBK

WT05688X01

Содержание CITY MULTI CMY-Q100VBK

Страница 1: ...ions or alterations Consult your dealer for repair Improper installation may result in water leakage electric shock or fire In the event of a refrigerant leak thoroughly ventilate the room If refrigerant leaks and comes in contact with an open flame toxic gases will be generated Properly install all parts according to the instructions in the Installation Manual If the wrong twinning pipe or wrong ...

Страница 2: ...kage unit name BC controller Twinning pipe a b PQRY P400YSHM A PQRY P200YHM A PQRY P200YHM A High pressure Low pressure c d High pressure e High pressure Twinning pipe Kit optional parts Twinning pipe Heat Source unit 1 Twinning pipe Heat Source unit 2 Twinning pipe Heat Source unit 2 Heat Source unit 2 PQRY P450YSHM A PQRY P250YHM A PQRY P200YHM A PQRY P550YSHM A PQRY P300YHM A PQRY P250YHM A Ø28...

Страница 3: ... above 120 C 248 F Place a wet towel on the refrigerant service valve before brazing the pipes Direct the blazing torch flame away from the adjacent cables and sheet metal to keep them from being damaged CAUTION 2 Connecting the twinning pipe kit 1 Braze the high pressure pipe 6 to the refrigerant service valve 2 Screw down the low pressure twinning pipe kit 1 to the sheet metal of the refrigerant...

Страница 4: ...Overlap the tape as shown in the left figure so that there will be no gap in between the insulation cover or field installed insulation material field supplied pipe Heat resistant insulation material field supplied Heat resistant insulation material field supplied field supplied pipe field supplied pipe 2High pressure twinning pipe BInsulation cover Tape field supplied To be gap free To be gap fre...

Страница 5: ...Related Links Model Number CMY Q100VBK CMY Q100VBK Installation Manual WT05688X01 ...

Отзывы: