66
7 FUNCTIONS
7.1 IO-Link Master Functions
IO-Link device setting automatic upload/download function
This function saves the parameter setting of the IO-Link device connected to each channel in the IO-Link module, and as
necessary, overwrites the parameter setting of the IO-Link devices.
Use this function to inherit parameter setting of an IO-Link device when replacing it.
The CQ LED flashes in green during uploading or downloading.
On the parameter setting window of the engineering tool or via a program, enable/disable automatic download of IO-Link
device parameters and automatic upload of directly modified IO-Link device parameters for each channel.
For details on setting parameters via a program, refer to the following.
Page 88 Data storage configuration
Description
The following table lists the IO-Link device conditions, and relevant settings and operations.
*1 No processing is performed if the parameter setting data in the connected IO-Link device is not compatible with the parameter setting
data in the IO-Link module.
*2 When the IO-Link module has no parameter setting data, parameter setting data will be uploaded even when the upload setting is
disabled.
*3 Depending on the IO-Link device setting, the upload operation may take precedence even when the download setting is enabled. (
Setting procedure
1.
Open the "CC IE Field Configuration" window.
For the master/local module RJ71GF11-T2
[Navigation window]
[Parameter]
[Module Information]
[RJ71GF11-T2]
[Module Parameter]
[Basic Settings]
[Network Configuration Settings]
2.
Open the "Parameter Processing of Slave Station" window.
From the list of stations, select an IO-Link module
[CC IE Field Configuration]
[Online]
[Parameter Processing of
Slave Station].
3.
Set "Method selection" to "Parameter Write".
IO-Link module condition
Setting details
Operation after executing the
function
Download setting
Upload setting
No parameter setting data
Disabled
Disabled
No processing
Enabled
Upload
Enabled
Disabled
Upload
Enabled
Upload
With parameter setting data
Disabled
Disabled
No processing
Enabled
Upload
Enabled
Disabled
Download
Enabled
Download
Содержание CC-Link IE Field NZ2GF12A-60IOLH8
Страница 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Страница 2: ......
Страница 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Страница 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Страница 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Страница 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Страница 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Страница 157: ...I 155 MEMO ...
Страница 161: ......