20
2 SPECIFICATIONS
2.1 General Specifications
2
SPECIFICATIONS
This chapter describes the specifications of the IO-Link module.
2.1
General Specifications
*1 The product specifications are satisfied only when all of waterproof plugs and waterproof caps are installed with the recommended
connectable devices and all screws are tightened with an appropriate torque.
*2 Do not use or store the IO-Link module under pressure higher than the atmospheric pressure of altitude 0m. Doing so may cause
malfunction. When using the IO-Link module under pressure, please consult your local Mitsubishi representative.
*3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power
distribution network and the machinery within premises.
Category
applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for the
equipment with the rated voltage of 300V or less is 2500V.
*4 This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used.
Pollution degree 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must be expected
occasionally.
To use the IO-Link module complying with the EMC Directive, refer to "EMC and Low Voltage Directives" in
this manual. (
Page 146 EMC and Low Voltage Directives)
Item
Specifications
Operating ambient
temperature
0 to 55
(0 to 40
for UL listed)
Storage ambient
temperature
-25 to 75
Operating ambient
humidity
Conforming to IP67
Storage ambient
humidity
5 to 95%RH, non-condensing
Vibration resistance
Compliant with JIS
B 3502 and IEC
61131-2
Frequency
Constant
acceleration
Half amplitude
Number of sweeps
Under intermittent
vibration
5 to 8.4Hz
3.5mm
X, Y, Z
10 times each in X,
Y, and Z directions
8.4 to 150Hz
9.8m/
Under continuous
vibration
5 to 8.4Hz
1.75mm
8.4 to 150Hz
4.9m/
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 (147m/
, 3 times each in X, Y, and Z directions)
Operating atmosphere
No corrosive gases
Operating altitude
0 to 2000m
Installation location
Inside/outside a control panel
Overvoltage category
or less
Pollution degree
2 or less
Equipment class
Class
Содержание CC-Link IE Field NZ2GF12A-60IOLH8
Страница 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Страница 2: ......
Страница 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Страница 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Страница 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Страница 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Страница 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Страница 157: ...I 155 MEMO ...
Страница 161: ......