English-38
U-11
Remote control (continued)
Carry out as necessary
LAN Remote control
By connecting the monitor and the computer using a network device such as a LAN hub as shown in Section P-7 and making
the network settings using the OSD menu and RS-232C communication control, you can perform remote control using the same
commands as those for RS-232C.
1. Setting
procedure
(1) Set the following network parameters using the OSD menu. (See page 47.)
• DHCP client ON/OFF, IP address, subnet mask and default gateway
(2) Set the IP address described above and the port number (63007 or 3007) using the application program of your computer to
perform the socket communication.
(3) Send the same control command as that for RS-232C via TCP/IP socket communication.
(4) Check the status sent from the monitor. When it is received successfully, the setting is completed.