Mitsubishi Electric AJ65BT-64DAI Скачать руководство пользователя страница 7

 CONDITIONS OF USE FOR THE PRODUCT 

 

 
(1)  Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions; 

i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead 
to any major or serious accident;    and   
ii) where the backup and fail-safe function are systematically or automatically 
provided outside of the PRODUCT for the case of any problem, fault or failure 
occurring in the PRODUCT. 

 

(2)  The PRODUCT has been designed and manufactured for the purpose of being used 

in general industries. 
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT 
NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON 
CONTRACT, WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY INJURY OR 
DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the 
PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED 
OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING 
CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY 
MANUALS, TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT. 
("Prohibited Application") 
Prohibited Applications include, but not limited to, the use of the PRODUCT in; 

  Nuclear Power Plants and any other power plants operated by Power companies, 

and/or any other cases in which the public could be affected if any problem or fault 
occurs in the PRODUCT. 

  Railway companies or Public service purposes, and/or any other cases in which 

establishment of a special quality assurance system is required by the Purchaser 
or End User. 

  Aircraft or Aerospace, Medical applications, Train equipment, transport equipment 

such as Elevator and Escalator, Incineration and Fuel devices, Vehicles, Manned 
transportation, Equipment for Recreation and Amusement, and Safety devices, 
handling of Nuclear or Hazardous Materials or Chemicals, Mining and Drilling, 
and/or other applications where there is a significant risk of injury to the public or 
property. 

 
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize 
use of the PRODUCT in one or more of the Prohibited Applications, provided that the 
usage of the PRODUCT is limited only for the specific applications agreed to by 
Mitsubishi and provided further that no special quality assurance or fail-safe, 
redundant or other safety features which exceed the general specifications of the 
PRODUCTs are required. For details, please contact the Mitsubishi representative in 
your region. 
 

Содержание AJ65BT-64DAI

Страница 1: ...hank you for buying the programmable controller MELSEC A Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AJ65BT 64DA U H E MODEL CODE 13J894 IB NA 66750 H 1612 MEE 1996 MITSUBISHI ELECTRIC CORPORATION ...

Страница 2: ...d to serious consequences Observe the precautions of both levels because they are important for personal and system safety Make sure that the end users read this manual and then keep the manual in a safe place for future reference Design Precautions WARNING Install a safety circuit external to the programmable controller that keeps the entire system safe even when there are problems with the exter...

Страница 3: ...ndertightening can cause drop of the screw short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction Do not directly touch the module s conductive parts or electronic components Touching the conductive parts could cause an operation failure or give damage to the module Wiring Precautions CAUTION Be sure to shut off all phases of t...

Страница 4: ...tions connected to the module Pulling the cables connected to the module can damage the module and cables or can cause a malfunction due to a cable connection fault Startup and Maintenance Precautions CAUTION Do not touch the terminals while power is on Doing so may cause malfunctioning Be sure to shut off all phases of the external power supply used by the system before cleaning or retightening t...

Страница 5: ......

Страница 6: ......

Страница 7: ... of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medica...

Страница 8: ...e following manuals User s manual for the CPU module or head module used Safety Guidelines This manual is included with the CPU module base unit or head module The CE mark on the side of the programmable controller indicates compliance with EMC and Low Voltage Directives 2 Additional measures To ensure that this product maintains EMC and Low Voltage Directives please refer to one of the manuals li...

Страница 9: ...etting or factory setting CC Link station type Remote device station Communication method Broadcast polling method Number of occupied stations 2 stations Connector terminal block 27 point terminal block M3 5 7screws Supported cable size 0 75 to 2 00mm2 Supported solderless terminal RAV 1 25 3 5 according to JIS C2805 RAV2 3 5 Module installation screw M4 0 7mm 16mm or larger screw tightening torqu...

Страница 10: ...itch Select the channel to perform offset adjustment or gain adjustment Positions other than 1 to 4 are not processed 4 OFFSET GAIN Offset gain setting switch The switch to set the offset gain values during test mode 1 OFFSET position Calibration mode for the offset value 2 GAIN position Calibration mode for gain 3 SET position When the switch is set from the OFFSET GAIN position which are modes t...

Страница 11: ...ate or the station number setting is out of range Flashing at regular intervals When the baud rate or station number setting is changed after power on or reset Flashing at irregular intervals When you forgot fitting the termination resistors or the module or CC Link dedicated cable is affected by noise Off Normal communication 8 Terminal block AJ65BT 64DAV AJ65BT 64DAI 1 DA 3 DG 2 DB 4 SLD 6 FG 8 ...

Страница 12: ...strong shock to the module Doing so may damage the module 2 Do not remove the module print board from the case This may cause breakdowns 3 Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris could cause fires damage or erroneous operation ...

Страница 13: ... subject the main unit to direct impact or vibration 5 Wiring the Data Link Cable This section introduces the wiring of the dedicated CC Link cable used for connecting the AJ65BT 64DAV DAI to the master module 5 1 CC Link dedicated cable connections The CC Link dedicated cable connections between the AJ65BT 64DAV DAI and master module are as follows 6 Wiring The precautions when wiring and the mod...

Страница 14: ...ith 0 1 to 0 47 F 25V or more voltage resistance parts specification to the input terminal of the external device 2 The wiring example to external device for AJ65BT 64DAI is shown below 1 Use two core twist shielded line for the wiring 2 When noise or ripple generates within the external wiring connect a condenser with 0 1 to 0 47 F 25V or more voltage resistance parts specification to the input t...

Страница 15: ...7 External Dimensions Diagram Unit mm inch 8 Marking and Information Disclosure for the Restriction on Use of Hazardous Substances in Electrical and Electronic Products Required by the New China RoHS ...

Страница 16: ... not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties ...

Отзывы: