 SAFETY PRECAUTIONS 

 

(Read these precautions before using this product.) 

 
Before using this product, please read this manual and the relevant manuals carefully and 
pay full attention to safety to handle the product correctly. 
The precautions given this manual are concerned with this product. Refer to the User’s 
Manual of the CPU module in use for details on the safety precautions for the 
programmable controller system. 
In this manual, the safety precautions are classified into two levels: "

WARNING" and 

"

CAUTION". 

 
Indicates that incorrect handling may cause hazardous conditions, 
resulting in death or severe injury.   
 
Indicates that incorrect handling may cause hazardous conditions, 
resulting in minor or moderate injury or property damage. 
 

Under some circumstances, failure to observe the precautions given under "

CAUTION" 

may lead to serious consequences. 
Observe the precautions of both levels because they are important for personal and 
system safety. 
Make sure that the end users read this manual and then keep the manual in a safe place 
for future reference. 
 

[Design Precautions] 

WARNING 

 Install a safety circuit external to the programmable controller that keeps the entire 

system safe even when there are problems with the external power supply or the 
programmable controller. Otherwise, trouble could result from erroneous output or 
erroneous operation. 
(1) The status of analog output changes depending on the setting of various functions 

that control the analog output. Take sufficient caution when setting for those 
functions. 
For details of analog output status, refer to Section 3.4.5 "Combinations of 
various functions" 

(2) Normal output may not be obtained due to malfunctions of output elements or the 

internal circuits. So build an external monitoring circuit that will monitor any single 
outputs that could cause serious trouble. 

 

WARNING 

CAUTION 

Содержание AJ65BT-64DAI

Страница 1: ...hank you for buying the programmable controller MELSEC A Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL AJ65BT 64DA U H E MODEL CODE 13J894 IB NA 66750 H 1612 MEE 1996 MITSUBISHI ELECTRIC CORPORATION ...

Страница 2: ...d to serious consequences Observe the precautions of both levels because they are important for personal and system safety Make sure that the end users read this manual and then keep the manual in a safe place for future reference Design Precautions WARNING Install a safety circuit external to the programmable controller that keeps the entire system safe even when there are problems with the exter...

Страница 3: ...ndertightening can cause drop of the screw short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction Do not directly touch the module s conductive parts or electronic components Touching the conductive parts could cause an operation failure or give damage to the module Wiring Precautions CAUTION Be sure to shut off all phases of t...

Страница 4: ...tions connected to the module Pulling the cables connected to the module can damage the module and cables or can cause a malfunction due to a cable connection fault Startup and Maintenance Precautions CAUTION Do not touch the terminals while power is on Doing so may cause malfunctioning Be sure to shut off all phases of the external power supply used by the system before cleaning or retightening t...

Страница 5: ......

Страница 6: ......

Страница 7: ... of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medica...

Страница 8: ...e following manuals User s manual for the CPU module or head module used Safety Guidelines This manual is included with the CPU module base unit or head module The CE mark on the side of the programmable controller indicates compliance with EMC and Low Voltage Directives 2 Additional measures To ensure that this product maintains EMC and Low Voltage Directives please refer to one of the manuals li...

Страница 9: ...etting or factory setting CC Link station type Remote device station Communication method Broadcast polling method Number of occupied stations 2 stations Connector terminal block 27 point terminal block M3 5 7screws Supported cable size 0 75 to 2 00mm2 Supported solderless terminal RAV 1 25 3 5 according to JIS C2805 RAV2 3 5 Module installation screw M4 0 7mm 16mm or larger screw tightening torqu...

Страница 10: ...itch Select the channel to perform offset adjustment or gain adjustment Positions other than 1 to 4 are not processed 4 OFFSET GAIN Offset gain setting switch The switch to set the offset gain values during test mode 1 OFFSET position Calibration mode for the offset value 2 GAIN position Calibration mode for gain 3 SET position When the switch is set from the OFFSET GAIN position which are modes t...

Страница 11: ...ate or the station number setting is out of range Flashing at regular intervals When the baud rate or station number setting is changed after power on or reset Flashing at irregular intervals When you forgot fitting the termination resistors or the module or CC Link dedicated cable is affected by noise Off Normal communication 8 Terminal block AJ65BT 64DAV AJ65BT 64DAI 1 DA 3 DG 2 DB 4 SLD 6 FG 8 ...

Страница 12: ...strong shock to the module Doing so may damage the module 2 Do not remove the module print board from the case This may cause breakdowns 3 Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris could cause fires damage or erroneous operation ...

Страница 13: ... subject the main unit to direct impact or vibration 5 Wiring the Data Link Cable This section introduces the wiring of the dedicated CC Link cable used for connecting the AJ65BT 64DAV DAI to the master module 5 1 CC Link dedicated cable connections The CC Link dedicated cable connections between the AJ65BT 64DAV DAI and master module are as follows 6 Wiring The precautions when wiring and the mod...

Страница 14: ...ith 0 1 to 0 47 F 25V or more voltage resistance parts specification to the input terminal of the external device 2 The wiring example to external device for AJ65BT 64DAI is shown below 1 Use two core twist shielded line for the wiring 2 When noise or ripple generates within the external wiring connect a condenser with 0 1 to 0 47 F 25V or more voltage resistance parts specification to the input t...

Страница 15: ...7 External Dimensions Diagram Unit mm inch 8 Marking and Information Disclosure for the Restriction on Use of Hazardous Substances in Electrical and Electronic Products Required by the New China RoHS ...

Страница 16: ... not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties ...

Отзывы: