Application examples
207
10
∗1
Adjustment parameter for adjusting the setting of another parameter.
1219
Tension PI gain tuning start/
status
0
1
1: Tension PI gain tuning starts.
1222
Target amplitude
9999
1%
Set the target amplitude for the limit cycle. Start tuning with a
small value and gradually increase the value while making
sure that tuning causes no problem.
1230
Winding/unwinding selection
0
0
0:Winding, 1: Unwinding
1235
Maximum winding diameter 1
2 mm
400 mm
Set the initial roll diameter (the maximum diameter of an
unwinding roll or the minimum diameter of a winding roll) with
high accuracy.
1236
Minimum winding diameter 1
1 mm
280 mm
1243
Gear ratio numerator (follower
side)
1
10
Set the gear ratio of the unwinding roller (shaft) with high
accuracy.
1244
Gear ratio denominator (driver
side)
1
12
1245
Sampling time for winding
diameter calculation
9999
0.1 s
Setting is recommended when the results of the roll diameter
calculation change significantly.
1247
Winding diameter change
increment amount limit
9999
0.1 mm
Setting
Pr.1247
= "9999 (initial value)" disables the roll
diameter calculation.
Be sure to change the setting from the initial value for the roll
diameter calculation.
1249
Number of averaging for winding
diameter calculation
4
4
Use this parameter to enable the primary delay filter relative
to the result of the roll diameter calculation.
1251
Winding diameter compensation
speed filter time constant
0 s
0.1 s
1255
Accumulated amount
9999
9999
9999: Initial roll diameter calculation disabled.
Pr.
Parameter name
Initial
value
Setting
value
Remarks
Содержание A800 Plus Series