English-56
OSD screen functions (continued)
CP MODE
You can enable the double-speed clear picture function (CP
mode).
Moving images displayed at 60 frames per second are
interpolated into 120-frame-per-second images for smooth
and sharp image quality.
OFF: Not
interpolated
MIDDLE: Interpolated (Typical)
HIGH:
Interpolated (for smoother and sharper image)
NOTE: Frame interpolation may cause noise and smear. To
reduce noise and smear, select OFF.
IR CONTROL
You can lock the wireless remote control.
Select from the following 4 modes using the
and
buttons and then determine the selected mode by pressing
the SET button.
NORMAL:
All the remote control operations are
enabled.
PRIMARY: The
fi rst MDT701S monitor of those multi-
connected via RS-232C is designated as
PRIMARY.
SECONDARY: MDT701S monitors other than the fi rst
one multi-connected via RS-232C are
designated as SECONDARY.
LOCK:
All the remote control operations are
disabled.
NOTE: When you hold down the DISPLAY button on the
wireless remote control for at least 5 seconds, the
NORMAL mode is activated.
You can lock the wireless remote control
independently from the control buttons on the rear
of the monitor. See page 58.
TILING
TILING is a function to divide or enlarge images and display
them across multiple screens. You can divide an input video
up to fi ve pieces horizontally and vertically and display
them on a single large screen comprised of up to 25 (5 x 5)
monitors tiled together.
NOTE: A same video signal needs to be input to each
monitor. When different monitors need to be
adjusted so that their tint can be identical, it
is recommended to use a signal distributor
(commercially available).
When TILING is activated, PIP, POP, SBS, and STILL
are disabled.
TILING doesn’t work in the REAL picture size mode.
While TILING is active, you cannot set MOTION of
SCREEN SAVER in the CONFIGURATION1 menu to
ON.
H MONITORS: Select the number of images obtained by
horizontal division.
V MONITORS: Select the number of images obtained by
vertical division.
POSITION:
Select the area you want to enlarge.
FRAME COMP.: When displaying an image across multiple
monitors, you can select the mode to
compensate for the bezel widths for
smooth and natural display.
ENABLE:
When you select ON, the image in the
selected area is enlarged on the screen.
HEAT STATUS
The statuses of the cooling fan, brightness, and internal
temperature are displayed.
NOTE: The cooling fan starts running according to the
operating temperature or when COOLING FAN is
ON in the SCREEN SAVER menu.
When the operating temperature substantially
exceeds the operation guaranteed range, the
message “TEMPERATURE WARNING” is displayed
on the screen.
POWER ON DELAY
You can adjust the delayed time until the power-on mode
is activated at the time of recovery from the sleep mode or
power-on.
The time is selectable from OFF and 2, 4, 6, 8, 10, 20, 30,
40, and 50 seconds.
TERMINAL SETTING
You can select the mode to display the HDMI1, HDMI2, or
DVI-D signal according to their signal format depending on
their source device.
HDMI SIGNAL:
Select this setting when displaying HDMI1, HDMI2, or
OPTION (when an OPS-compliant computer is mounted).
Select FULL when displaying the signal that uses all 256
levels (from level 0 to 255). This mode is used primarily
when input comes from a computer.
Select LIMITED when displaying the signal that uses 16
to 235 levels of 256 levels for each of R, G, and B. This
mode is used primarily when input comes from a video
device.
HDMI MODE:
Select this setting when displaying the HDMI1 or HDMI2
signal.
Select HDMI-HD when the source device is a video
device.
Select HDMI-PC when the source device is a PC.
DVI MODE:
Select this setting when displaying the DVI-D signal.
Select DVI-PC when the source device is a PC.
Select DVI-HD when the source device is a video
device.
DDC/CI
Use to turn ON or OFF the DDC/CI communication function.
Select ON for normal use.